Suncenter Air Driven Liquid CO2 Pressure Booster Filling Pump for
XPS Foaming MachineWe offer the most complete range of Air driven
liquid pump models in the industry measured for:Capability of
ultimate pressure, flow or output horsepower. Compatibility with a
broad variety of liquids, such as oil, water and chemical
applications.SUNCENTERpumps are air driven at a drive air pressure
of 1bar to 8bar (14.5 psi to116 psi) by the normal air compressor.
Basically the principle of operation is similar to a reciprocating
amplifier where control of the piston at the end position is
regulated by a pilot operated 4/2 way valve.Suncenter pumps feature
a large air piston joint to a smaller diameter plunger. The
pressure ratio is the difference of these two areas and is the
method of determining maximum outlet pressure. Higher pressures
obtained by using higher pressure ratios.Suncenter model numbers
reflect the pumps nominal pressure ratios, while the technical data
indicates exact ratios. The outlet pressure is easily to set
through a simple air regulator. By multiplying the pressure ratio
by the available shop air pressure, the nominal liquid pressure can
be calculated.Applications include: Pressure
testing Suncenter Air Driven Pressure Booster Filling Pump for
CO2 foaming Work holding/power
clamping Jacking/lifting Valve actuator
control Hydraulic cylinder actuation Press safety
overload devices Liquid CO2 fire extinguisher
filling Metering Precision lubrication and
spraying Liquefied gas transferKey features include:
Compressed Air driven - no electricity required (connect to
normal air compressor)In order to extend the lifetime of the pump,
the driving air pressure should not be higher than 8 barNo airline
lubricator required Pressures to 640Mpa (6400 bar) Wide range
of models with different ratiosBuilt-in-cooling on most models Easy
to install, operate and maintainBest price / performance ratio No
heat, flame or spark risk and explosion proof Automatic pressure
holding,whatever the cause of the pressure drop, the
Suncenter pump will automatically start, keep the loop
pressure constantDGGD Series Liquid Pumps(Double acting, single air
drive head)They are characterized by the same features as the DGG
pumps single acting, single air drive head types, but they have
less pulsations and deliver approx. 50 % more flow.Technical
specification ModelPressure Boost RatioDriven air
pressure PLFormula to calculate outlet pressureMAX
OutletPressure(bar)*Liquid inlet ConnectionLiquid outlet
ConnectionMAX Flow (L/min)**DGGD44:12-8
bar4XPL32NPT1/2NPT1/270.00DGGD66:12-8
bar6XPL48NPT1/2NPT1/248.60DGGD1010:12-8
bar10XPL80NPT1/2NPT1/230.61DGGD1616:12-8
bar16XPL128NPT1/2NPT1/219.73DGGD2828:12-8
bar28XPL224NPT1/2NPT1/211.30DGGD4040:12-8
bar40XPL320NPT1/2NPT3/87.69DGGD6464:12-8
bar64XPL512NPT1/2NPT3/84.94DGGD8080:12-8
bar80XPL640NPT1/2NPT3/83.96DGGD100100:12-8
bar100XPL800NPT1/2NPT3/83.13DGGD130130:12-8
bar130XPL1040NPT1/2M14*1.52.40DGGD175175:12-8
bar175XPL1400NPT3/8M14*1.51.81DGGD255255:12-8
bar255XPL2040NPT1/4M14*1.51.23DGGD400400:12-8
bar400XPL3200NPT1/4M14*1.50.79The outlet liquid pressure=Driven air
pressure*boost ratioIn order to extend the lifetime of the pump,
the driving air pressure should not be higher than 8
barSUNCENTERpumps are self-priming. In general it is not necessary
to use an air line lubricator. The liquid to be pumped flows into
the suction chamber by the up-stroke of the drive piston. By this
suction effect, the inlet check valve is opened and the outlet
check valve is closed. The down-stroke generates the pressure at
the liquid side. The inlet check valve is closed and the outlet
check valve is opened by the generated pressure. SUNCENTER liquid
pumps cycle automatically, where the pressure is built up the
numbers of cycles slow down, the pump stops automatically when the
output pressure forces are equal. The pump restarts with a slight
drop in the outlet pressure or an increase in the air drive
pressure. Pump performance can be affected by a number of
conditions, such as freezing of muffler or pilot valves (which is
caused by moisture in air lines), inadequate inlet air line sizes
and dirty filers. Don't reduce the indicated port sizes and consult
SUNCENTER for exact flow conditions not shown in charts.Dongguan
Suncenter Fluid Control Equipment Co., Ltd is the member company of
Suncenter Group, which is located in Dongguan city of Guangdong
province in China. With more than 15 years experiences in fluid
pressure exchange and controlling field, we provide various kinds
of pneumatic and hydraulic booster pumps, systems and solutions to
the customers all over the world. Due to our best product quality,
competitive price as well as excellent after-sales service, we have
win a great reputation in the field. Our main products
including:High Pressure Booster Pumps (Air Driven Gas Booster Pump,
Air Driven Liquid Pump, Air Amplifiers)High Pressure Systems
(Gas/Liquid Booster Stations,FM200 filling machine, Tube Exp
Related products about Suncenter Air Driven Liquid CO2 Pressure Booster Filling Pump for XPS Foaming Machine
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup