Anestesia Machine Hospital Vaporizer Anesthesia Machine

Anestesia Machine Hospital Vaporizer Anesthesia Machine Without VentilatorModel:MCA-850Prospective service and supportMCA-850 Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for preventing cyanosis and necessary alarm system. During the anesthesia, the patient's respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.Power On Self TestThe automatic conversion for standby power while AC power outage,  keep working  not less than 1 hour.Component DetailsNa Lime Tank: Equipped with international advanced one-piece soda lime cans,it can be fast replaced with  hands  and  withstand temperatures up to 134ºCCircuit: Metal integrated breathing circuit, Perfect function of gas sealing under high temperature disinfection, and easy to cleaning and disinfected.Flowmeter: 5-Tubes flowmeter;1. Assure that O2 output not lower than 20%2. NO2 automatically off while O2deficiencyDisplay & Operating  Interface:10.4'' LCD Display Screen, can feedback patient dataShuttle button: More accurateVaporizers:  En flurane/ Iso flurane/ Sevo flurane(Option: Halothane)  Setting Range:  0.5~5%What is the specification of our anesthesia machine?Physical specifications Screen: 10.4 ''  LCD  Display ScreenSuitableAdult & Child Mode:pneumatically powered and electrically controlled systemWorking Mode:Closed; Semi-Closed; Semi-OpenCircuitBreathing circuit integrated standardsFlowmeters:5 Tubes Flowmeters:  O2:0.1~10L/Min,  N2O:0.1~10L/Min; Air: 0.1~10L / MinTrolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisionsDrawer unitTWO drawers  totally extractableTechnical Specifications:Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ;   NO2: 0.32 MPa to 0.6 MPa.safety valve  21%Oxygen Flush: 25~75 L/minmodes of ventilationA/C, IPPV, SIPPV, IMV, SIMV, PCV, VCV, PEEP, MANUAL, SIGHPEEP:0 ~ 2.0 kPaInspiratory trigger pressure-1.0kPa ~ 2.0 kPaIMV frequency:..I/E Ratio8:1 ~ 1:10, Has the inverse ratio ventilationTidal Volume0 ~ 1500 MLInspiratory Plateau0~1sO2 Concentration21%~100%Sighone deep breath per 70 ~ 120 controlled respirations, the inspiration time is 1.5 times of the setting pointMaximum safety pressure:≤ 12.5 kPaPressure limit range:0 ~ 6.0  kPaAirway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.2kPa~5.0kPa;   Upper: 0.3~6.0  kPa±0.2 kPaTidal volume alarm: Audible and visual and with yellow and red color indicatingupper alarm: 50 to 2000ml, lower alarm: 0~1800mlOxygen concentration alarm: Audible and visual and with yellow and red color indicatingupper alarm: 21% ~100%;  lower alarm:10%~80%Power Supply AlarmAc/dc power supply are after failing to send out alarm immediatelyAlarm Time: keep >120sThe airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.Operating conditionsAmbient temperature10 ~ 40Relative humidityno higher than 80 %Atmospheric pressure:860 hPa ~ 1060 hPaPower requirement: 100-120 Vac, 50/60 Hz;  Attention: the AC power supply used for the anesthesia machine must be well   grounded.Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. StorageAmbient temperature: -15 ~ +50Relative humidity: no higher than 95 %Atmospheric pressure: 86 kPa ~ 106 kPa. It should be stored in a room without corrosive gas and well ventilatedPackagepackaging boxcomply with the requirement of GB/T 15464 Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation Moisture protection and rain protection to ensure that product is protected from natural damage. Safty & AlarmOxygen AlarmIt alarms when the oxygen  supply from pipe or cylinders lower than 0.2MPaVentilation Volume AlarmLower: 0~12L/Min;   Up: 18L/ MinPower AlarmIt Alrmas while AC and DC supply failure ; Keep alraming  time: >120sAir Tract Pressure AlarmLower: 0.2kPa ~5.0 kPa;  Up: 0.3kPa ~ 6.0kPaCompany Profile: /* March 10, 2023 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1