Anestesia Machine Hospital Vaporizer Anesthesia Machine With
VentilatorModel:MCA-850 What is the detail of our
hospital anesthesia equipment?Prospective service and
supportMCA-850 Anesthesia Machine is equipped with an accurate
dedicated anaesthetic vaporizer and a safety device for preventing
cyanosis and necessary alarm system. During the anesthesia, the
patient's respiratory functions can be managed by using a
microcomputer controlled pneumatic electrically controlled
synchronizing anesthesia respirator. Each connection part of the
whole machine is a standard interface. A highly efficient and large
volume soda lime absorber can minimize the re-inhalation of carbon
dioxide by the patient.Power On Self TestThe automatic conversion
for standby power while AC power outage, keep working
not less than 1 hour. Component DetailsNa Lime
Tank: Equipped with international advanced one-piece soda lime
cans,it can be fast replaced with hands and
withstand temperatures up to 134ºCCircuit: Metal integrated
breathing circuit, Perfect function of gas sealing under high
temperature disinfection, and easy to cleaning and
disinfected.Flowmeter: 5-Tubes flowmeter;1. Assure that O2
output not lower than 20%2. NO2 automatically off while
O2deficiencyDisplay & Operating Interface:10.4'' LCD Display
Screen, can feedback patient dataShuttle button: More
accurateVaporizers: En flurane/ Iso flurane/ Sevo
flurane(Option: Halothane) Setting
Range: 0.5~5% What is the specification of our
anesthesia machine? Physical
specifications Screen: 10.4 '' LCD Display
ScreenSuitableAdult & Child Mode:pneumatically powered and
electrically controlled systemWorking Mode:Closed; Semi-Closed;
Semi-OpenCircuitBreathing circuit integrated standardsFlowmeters:5
Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min; Air:
0.1~10L / MinTrolley: Fitted with 4 nos anti-static rubber
castors; two of which are lockable for braking and easy
maneuverability with foot operated brake provisionsDrawer unitTWO
drawers totally extractableTechnical Specifications:Gas
requirement: Medical oxygen and nitrous oxide with a pressure
ranging from O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6
MPa.safety valve 21%Oxygen Flush: 25~75 L/minmodes of
ventilationA/C, IPPV, SIPPV, IMV, SIMV, PCV, VCV, PEEP, MANUAL,
SIGHPEEP:0 ~ 2.0 kPaInspiratory trigger pressure-1.0kPa ~ 2.0
kPaIMV frequency:..I/E Ratio8:1 ~ 1:10, Has the inverse ratio
ventilationTidal Volume0 ~ 1500 MLInspiratory Plateau0~1sO2
Concentration21%~100%Sighone deep breath per 70 ~ 120 controlled
respirations, the inspiration time is 1.5 times of the setting
pointMaximum safety pressure:≤ 12.5 kPaPressure limit range:0 ~
6.0 kPaAirway pressure alarm: Audible and visual and with
yellow and red color indicatingLower: 0.2kPa~5.0kPa;
Upper: 0.3~6.0 kPa±0.2 kPaTidal volume alarm: Audible and
visual and with yellow and red color indicatingupper alarm: 50 to
2000ml, lower alarm: 0~1800mlOxygen concentration alarm: Audible
and visual and with yellow and red color indicatingupper alarm: 21%
~100%; lower alarm:10%~80%Power Supply AlarmAc/dc power
supply are after failing to send out alarm immediatelyAlarm Time:
keep >120sThe airway pressure continues to be higher than 15
hPa ±1 hPa for 15s±1s, then the machine will raise an audible
alarm, the pressure will be displayed in red and the continuous
high pressure red alarm wording is displayed on the screen of the
anesthetic respirator.Operating conditionsAmbient temperature10 ~
40Relative humidityno higher than 80 %Atmospheric pressure:860 hPa
~ 1060 hPaPower requirement: 100-120 Vac, 50/60
Hz; Attention: the AC power supply used for the
anesthesia machine must be well grounded.Attention: the
anesthesia machine used must be equipped with a carbon dioxide
monitor complying with ISO 9918:1993, an oxygen monitor complying
with ISO 7767:1997 and an expiratory gas volume monitor complying
with 51.101.4.2 of Medical Electrical Equipment Part II: Special
Requirements for Safety and Basic Performance of Anesthesia
System. StorageAmbient temperature: -15 ~ +50Relative
humidity: no higher than 95 %Atmospheric pressure: 86 kPa
~ 106 kPa. It should be stored in a room without corrosive gas
and well ventilatedPackagepackaging boxcomply with the requirement
of GB/T 15464 Between the packaging box and product, soft
material with appropriate thickness provided to prevent loosening
and mutual friction during transportation Moisture protection
and rain protection to ensure that product is protected from
natural damage. Safty & AlarmOxygen AlarmIt alarms when the
oxygen supply from pipe or cylinders lower than
0.2MPaVentilation Volume AlarmLower: 0~12L/Min; Up:
18L/ MinPower AlarmIt Alrmas while AC and DC supply failure ; Keep
alraming time: >120sAir Tract Pressure AlarmLower: 0.2kPa
~5.0 kPa; Up: 0.3kPa ~ 6.0kPa /* March 10, 2023 17:59:20
*/!function(){function s(e,r){var
a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Related products about Anestesia Machine Hospital Vaporizer Anesthesia Machine with Ventilator
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup