Basic Info.Model NO.KRS-300E/SN2-MCertificationSASO, RoHS, CB, CCC,
ISO9001, CEWorking Medium R410A Heat Source TypeAir Source Heat
PumpCop4.17Noise58
dBTrademarkKolantSpecification30KWOriginGuangzhou, ChinaHS
Code8418612090Product DescriptionNowadays, due to the constant rise
in oil prices, there is an increasing need for energy efficient
products that provide greater savings to users. The hotel industry
is among the most energy-intensive sectors of the economy, meaning
soaring costs for operating the facilities. Most of the hotels use
conventional and energy-inefficient systems such as conventional
boilers in order to produce domestic hot water. The need to find
more economical energy upgrading solutions for existing
installations is imperative. The attention of interested parties is
mostly directed towards the use of heat pumps or solar energy.These
and many advantages prove that the use of a heat pump is the best
solution for the needs of a hotel.Main advantages of using a heat
pump compared to a boiler:• Energy upgrading of buildings• Energy
efficiency and operating cost reductions up to 70%• Return on
investment approximately within 3 yearsMain advantages of using a
heat pump compared to a central solar field:• Faster return of
investment• Less space required• Less need for maintenance• Smaller
volume of hot water storage tanks and hence less space for boiler
roomsSolutions by Kolant for air to water production•
Specifically designed for heating applications Nominal capacity
from 10kW to 250kW• Maximum water temperature 65°C• Guaranteed
operation without the performance reduction nor the temperature of
the produced water, for ambient temperatures up to 43°C• Choice of
anti-corrosion protection• External heat source control•
Master-slave units factory-installed parallel operation•
Newly-designed Flying Bird IV fans with very low noise level• Pro
Dialog Plus controller with liquid crystal display• Communication
with existing MODBUS systemsPowerful Heat Pumps for Commercial Hot
WaterEnergy consumption of hot water accounts for a considerable
percentage in commercial buildings. According to some
investigation, this percentage can even be as high as 40% in some
hotels, nursing homes, hospitals etc. Heat pumps, however, generate
hot water mostly with renewable energy are especially suitable for
commercial hot water project. Using KOLANT heat pumps as the
heating devices or replacing those existed boilers in commercial
buildings makes great benefits in economic and environmental
prospects. With large capacity range from 10kW to 250kW, KOLANT
commercial heat pumps provides various choices for users to get the
most cost-effective solution for hot water
projects.ModelKRS-800E/SN1-VKRS-1000E/SN1-VKRS-1250E/SN1-VKRS-1600E/SN1-VKRS-2000E/SN1-VKRS-2500E/SN1-VPower
supplyPh-V-Hz380V/3PH/50HZ380V/3PH/50HZ380V/3PH/50HZ380V/3PH/50HZ380V/3PH/50HZ380V/3PH/50HZWorking
tempºC-15ºC~43ºC-15ºC~43ºC-15ºC~43ºC-15ºC~43ºC-15ºC~43ºC-15ºC~43ºCMax.
outlet Water temp.ºC60ºC60ºC60ºC60ºC60ºC60ºCWater Heating
(A20/W55)CapacityKW80100125160200250Hot water
yieldL/h172021502687343942995374InputKW19.32430.338.64860.6Rated
currentA31.7939.5349.9063.5779.0599.80Hot water
yieldm3/h Max. input
consumption KW28.953645.4557.97290.9Max.
input currentA47.6859.2974.8595.36118.58149.70Wire
controllerType Intelligent &
LCDIntelligent & LCDIntelligent
& LCDIntelligent &
LCDIntelligent & LCDIntelligent
& LCDThe length of wiresm121212121212set
Temp.ºC25~6025~6025~6025~6025~6025~60Water systemmaterials of water
pipe copper copper copper copper copper copper water
flowm3/h17.221.526.934.443.053.7Water different
pressureKpa606060707070Diameter,water inlet
pipemmDN50DN50DN50DN65DN65DN65Diameter,water outlet
pipemmDN50DN50DN50DN65DN65DN65Design
pressure Mpa2.8/0.022.8/0.022.8/0.022.8/0.022.8/0.022.8/0.02Outdoor
noise level (1 meter)dB(A)707070727272Outdoor
unitDimension(L*W*H)mm2000/980/1960 mm2000/980/1960 mm2000/980/2062
mm2000*2160*23352000*2160*23352000*2160*2335Packing(L*W*H)mm2130/1100/2150
mm2130/1100/2150 mm2130/1100/2260
mm2090*2290*24602090*2290*24602090*2290*2460NG/WGkg Testing
condition: ambient Dry/Wet Bulb Temp.: 20ºC/15ºC; Water
Inlet/Outlet Temp.: 15ºC/55ºC.
Related products about 80kw~250kw Commercia Chiller Hot Water Heaterl Air to Water Heat Pump
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup