Product DescriptionProduct Name: Standard size 2012-200
membrane Manufacturing and ExportersActive Area, 7.5(0.7) Ft2
(m2)Removal rate, around 97%Water production rate,200GPDTesting
pressure, 65PSITest temperature, 25ºCPacking detail,
25PCS/CTNDetailed PhotosProduct ParametersSeriesModelActive
areaSalt rejectionWater outputTest
prssureFt2(m2)%GPDPSI15101510-502(0.17)9750651510-753(0.25)977565ECO1812-50
9L3.5(0.35)9750651812-75 9L3.5(0.35)977565238mm1812-50
13L4(0.4)9750651812-75 13L4(0.4)9775652012-100
13L5(0.5)97100654000ppm1812-754(0.4)95751202012-804.5(0.45)96801202012-1005(0.5)96.5100120Regular1812/20122000ppm1812-50
11L4(0.4)9750651812-75 11L4(0.4)9775652012-80
12L4.5(0.45)9780652012-100 13L5(0.5)97100652012-125
13L5.2(0.52)97125652012-1506(0.6)97150652012-1806(0.6)97180652012-2007.5(0.7)972006530123012-2008.6(0.8)97200653012-25010.8(1)97250653012-30013(1.2)97300653012-40015(1.4)97400803012-60020.5(1.9)966009030133013-40015(1.4)97400803013-50018.3(1.7)96500803013-60020.5(1.9)966009032133213-60020.5(1.9)96600903213-80026(2.5)968009034133413-80028(26)96800903413-100032(3)95100090Inline
RO1812-754(0.4)9750/75/10065Packaging & Shipping16PCS/CTN,
32*32*34CM, 8.5KGS/CTNInstallation InstructionsInstallation
InstructionsUnscrew the nut on the membrane shell cover at the
inlet water connection end, take out the inlet water pipe, then use
the membrane shell wrench to loose the membrane shell cover. Take
the RO membrane from its packaging, put the end of the membrane
with 2 O-rings into the RO membrane shell (See The following
Diagram ) and push it in, finally screw the membrane shell cover
back on, and tighten it with membrane shell wrench, put the inlet
water pipe back into the inlet water connector and screw the nut
tightly, then push the membrane shell card into the large single
clip. Direction For Use1. When installing the RO
membrane, you should pay attention to the direction of the
membrane;2. When installing the RO membrane, you should first
make sure that one end of the membrane has 2 O-rings;3. When
installing, be sure to put the end with the O-ring into the end of
the membrane shell with the pure water connection, for correct
installation you need only a little force to put the RO membrane
into the membrane shell, if you encounter too much resistance,
please do not force the membrane into the shell, or it could lead
to permanent damage to the membrane shell or membrane components
(the membrane manufacturer does not take the responsibility for
replacing components due to damage made during
installation);4. Damage to the membrane shell and membrane
element caused under above mentioned situation is not covered by
the warranty.Company ProfileOur AdvantagesA. Full range RO
membranes 50GPD to 1000GPD for home use.B. Self-produced membrane
sheet.C. Each roll of membrane sheet will be tested before bulk
production.D. Each finished membrane will need pass vacuum testing,
to make sure salt rejection rate.E. OEM and ODM orders are
welcomed.FAQFAQs on Reverse Osmosis RO membrane OEM
manufacturingQ1: What type of RO membrane is avaliable in your
company?A1: In general, Hikins has Domestic RO membrane and
Industrial RO membrane, For Domestic RO membrane, Hikins has
Municipal Tap water RO membrane, Rural Area Under Ground water RO
membrane, High-flow Low pressure RO membrane, and Brackish water RO
membrane. For Industrial RO membrane, Hikins has Low Pressure
Engergy saving RO membrane, BW Brackish water desalination RO
membrane, FR Fouling Resistant RO membrane, as well as XLE Extreme
Low Pressure RO membrane, and High Salinity Brackish Water
Desalination RO membrane. Q2: What is Salt Rejection Ratio?A2:
The Salt rejection describes the quality of salt removed from the
Reverse Osmosis feed water stream as a percentage. It's one of the
key element of the RO membrane quality, however, other essential
elements such as RO membrane performance durability, stability,
application scope in different region, and permeate flow output at
the same pressure will all be the important factors to judge the
quality of the membrane. Q3: Is the Salt reation of the RO
membrane the higher the better?A3: This will be depending on the
feed water quality, if the feed water quality is good, even a 90%
salt rejection membrane will be workable, if the feed water is with
bad quality and with brackish water environment, a higher salt
rejection above 95% is an ideal choice. For any membrane that meet
the local drinking water standard will be a good membrane. Q4:
Is there are any other element we need to take into consideration
when selection the RO membrane?A4: Yes, the pre-treatment filter
cartridge and pre-treatment system will affect the RO membrane
performance as well, please select good quality filters and
pre-treatment system. Q5: Why there are white foam-like water
being in the treated water at the initial usage?A5: To preserve the
RO membrane for a long shelf-life, and prevent the membrane from
being oxydized, a water soluble protection
Related products about Standard Size 2012-200 Membrane Manufacturing and Exporters
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup