Hospital waste harmless treatment equipment with disinfection
system 1. High temperature steam killing disinfection
equipment brief:Technical principle and characteristics:.the
principle of pressure steam sterilization treatment method is that
the medical waste after sorting and crushing runs for more than 20
rain under the process conditions of 100 kPa. 121cc. and
the pressure steam penetrates the inside of the object. so
that the protein of the microorganism is coagulated and denaturated
and killed.The treated medical waste is sent to sanitary landfill
or incinerated.This method also applies to the disinfection of
contaminated work clothes, syringes, dressings, microbial media,
etc2. Product picture :3.Effect parameter:
The main technical
parameters of pressure steam sterilization are temperature, steam
quality and action time. The size of waste feed will affect the
steam penetration, the treatment cycle time will affect the
thoroughness of sterilization, and the incomplete removal of air in
the container will affect the internal temperature of the
sterilizer. 4.Product advantage and disadvantage :
Advantages and disadvantages:
compared with low investment, low operating cost, easy to detect,
low residue risk, good disinfection effect. suitable for a wide
range of treatment advantages. The main disadvantage is that
the volume and appearance are basically unchanged. There may
be air pollutant emissions. easy to produce odor. formaldehyde,
phenol, mercury and other substances can not be
treated. 5.High temperature steam sterilization process:
The
treatment process of medical waste includes: medical waste --
collection -- transportation -- high-pressure steam sterilization
disposal center -- storage -- sterilization -- health
landfill. 1Feeding: Pour medical waste into sterilizer through
feeding machine, close the front door and wait for sterilization
treatmen2Sterilization treatment: after the current door is closed,
PLC gives instructions to the sterilizer and starts to run the
sterilization procedure preset by the sterilizer for sterilization
treatment.3Pulsation: Vacuumize and steam into the sterilizer
repeatedly for several times, and then vacuumize again. When the
indoor pressure is high enough to pulsate offline, the program will
turn to the heating stage. After this stage, the removal rate
of cold air in the inner chamber can reach more than 99%, to ensure
that there is no dead corner in the inner chamber, to ensure that
the sterilization is qualified.4Heating up: steam enters the inner
chamber through the interlayer of sterilizer to heat the waste. At
the same time, the inner trap is opened intermittently to discharge
the water generated after steam condensation. After the inner
chamber temperature reaches the set value, the procedure is
transferred to sterilization stage.5Sterilization: high temperature
steam sterilization equipment in many forms, the common vertical
sterilization cabinet, horizontal sterilization
cabinet; Pressure is atmospheric (the normal pressure in the
cabinet is not greater than atmospheric pressure), pressure type
(the normal pressure in the cabinet is greater than atmospheric
pressure); According to the type and quantity of medical
waste, sterilization requirements, etc. Because medical waste
is the main performance of the pathogenic infection, so its
placement in the steam atmosphere of a certain temperature and keep
a certain time, using the water vapor latent heat release, cause of
pathogenic microorganisms in the medical waste protein degeneration
and coagulation and death, to medical waste harmless, achieve the
goal of safe disposal. Start the sterilization timer, during
which the chamber inlet valve is controlled by the chamber
temperature and pressure to ensure sterilization within a certain
temperature range. 6Exhaust steam: the exhaust valve is
opened, and the steam in the inner chamber is discharged under the
action of internal and external pressure difference. After the
action of heat exchanger, most of the steam is condensed into
water, and a small part of the steam is filtered and discharged to
the atmosphere. When the pressure in the inner chamber reaches
the set value, it turns to the drying stage.7Drying: the vacuum
pump is opened to vacuumize the inner chamber, while the interlayer
maintains a certain pressure and temperature to play a drying role.
The drying completes the closing of the rear air valve and the
vacuum pump, and the program ends. 8Post-treatment: after
treatment, the medical waste should be broken and destroyed, so
that the medical waste can not be identified, so as to avoid being
recycled by lawbreakers and endanger the society and the
masses. Due to the complexity of medical waste, waste liquid,
waste gas, volatile organic compounds, heavy metal ions and other
harmful substances will be discharged to the environment during the
disposal process. Therefore, the disposal effect of
high-temperature stea
Related products about Hospital Waste Harmless Treatment Equipment with Disinfection System
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup