Water Source Heat Pump for Hot Water

Multi function air to water heat pump Heating/cooling system and hot water Central air conditioner High COP heat pump Low noise Air source heat pump Air to water heat pump Air to water Multi-functional Heat pump * Heat Pump(Multi-use): Room Heating, Air Conditioning and Domstic Hot Water Air to water Multi-functional House Heat Pump can satisfy all your needs at your home. You not only can get the room heating in winter and have the air conditioning in summer, but also enjoy the hot water for bath and domstic use * Saving: Reducing heating costs up to 65% Alto Air to water Multi-functional House Heat Pump will dramatically reduce heating costs up to 65%. It only needs a bit of electrical energy to start extracting the heat energy from the air, which requires only 1 kilowatt of electricity to transfer 3 to 5 kilowatt of heat into your home. That means: 2/3 free energy from air + 1/3 electrical energy = Warm and Safe Water * Environment: Less CO2 emission for better environment Alto Air to water Multi-functional House Heat Pump does not use any combustion process or energy to generate heat. It only uses little electricity to transfer the energy from air to water water(ground) source heat pump cooling & heating Modle  CRS-4I  CRS-8ICRS-12IICRS-20IICRS-40II  CRS-70IICRS-80IICRS-120IICRS-165IICRS-200IICRS-240IICRS-300IICooling capacitykW481220406080120165200240300Heating capacitykW4.38.61322456991131176213260315Cooling input powerkW0.81.62.54.18.312.716.625.332.339.24758.8heating input powerkW0.951.92.84.710.414.620.627.239.147.357.770Cooling input currentA4.38.44.57.51522.729.545.5587185106Heating input currentA5.110.15.28.518.6273750.37186106127Underground working condutionCooling capacitykW3.97.711.519.538.457.676.9115.3158.6192.3230.7288.4Heating capacitykW4.28.212.521.243.266.385.1125.9169.2204.8250302.8Cooling input powerkW0.811.62.44.18.212.416.724.932.339.24758Heating input powerkW0.931.82.74.81015.420.329.241.249.960.973.8Cooling input currentA4.28.54.57.51523.531.54660.272.986105Heating input currentA4.89.85.39.11829.137.555.376.692.8113.2137Underground circle type nominal working conditionCooling capacitykW3.87.611.419.1385776.2114.1157190.3228.4285.5Heating capacitykW4.18.112.320.9426580.1124.6167.5202.3247.5299.8Cooling input powerkW0.81.62.44.28.412.716.925.332.939.847.859.8Heating input powerkW1.12.13.15.110.516.22031.141.850.561.874Cooling input currentA4.28.44.77.915.623.631.94761.17488111Heating input currentA5.711.15.89.61830.137.857.877.793114139.3Circle water working conditonCooling capacitykW3.67.210.918.136.254.372.4108.7149.5181.3217.5271.9Heating capacitykW4.710.315.626.454.684.5104161.9218266330390Cooling input powerkW0.951.92.94.89.514.219.128.636.444.25366.3Heating input powerkW1.042.33.4612.118.723.135.943.653.26678Cooling input currentA5.110.35.69.317.626.43653.167.78298123.3Heating input currentA5.512.36.711.422.534.74366.78198122.7145power220V/50Hz380V/50HzCompressortypeRotorScrollDouble-Screw-Refrigeration CompressorsNO.UNIT111112221111Energy regulation%0, 1000, 1000, 1000, 1000, 1000, 50, 1000, 50, 1000, 50, 1000, 25, 50, 75, 100Heating source side heat exchanger TypePlate type heat exchanger   Horizontal type shell& tube heat exchanger Underground water make cooling water flowm 3 /h0.360.711.73.45.26.710.814.2162024Underground water make heating  water flowm 3 /h0.420.831.32.14.26.28.312.417212531Underground circle type nominal working condition cooling water flowm 3 /h0.71.42.23.67.211.213.721.428.8354252Underground circle type nominal working condition heating water flowm 3 /h0.651.31.963.36.59.813.119.6273339.549Water tube interfacemmDN20DN20DN20DN25DN40DN50DN80DN100User side heat exchangerTypePlate type heat exchanger  Horizontal type shell& tube heat exchanger cooling water flowm3/h0.71.42.13.46.810.313.72028.334.441.352Heating water flowm3/h0.741.52.23.87.711.815.622.53036.644.754.2Water tube interfacemmDN20DN20DN20DN25DN40DN50DN80DN100Protector1High and low pressure protection, 2nti-freeze protection, 3 emperature protection, 4safety valve, 5overload protection, 6Reverse phase,7Lack of phase, 8Separation of water and electricity, ect.RefrigerantTypeR410a/R407cThrottle Modethermostatic expansion valveweightkg0.81.21.931219233945566782SizeLongmm70970970981017602400240025602560265028902890Widemm3593593594205006506508809009009001100Highmm59259259259011501210126013001335143014301530Noise≤ dB(A)353538425560606265666668Weightkg43.84569933405706128501150130014501850Note: 1, Underground circle type nominal cooling working condition: User side water inlet/outlet temperature 12º C/7º C; Source side water inlet/outlet temperature 25º C/30º C                            Underground circle type nominal Heating working condition: User side water inlet/outlet temperature 40º C/45º C; Source side water inlet/outlet temperature 10º C/5º C                      2, Underground water type nominal cooling workingcondition: user side water inlet/outlet temperature 12º C/7º C; source si