Hot Selling Geothermal Source Water Chiller Heat Pump for Hotel Villa Use

Hot Selling Geothermal Source Water Chiller Heat Pump for Hotel Villa Use1. Unit features-Eurostars water cooled geothermal source water chiller heat pump(1)High efficiency and energy saving;(2) Low noise and reliability operation; (3)Intellectualized control system; (4)Easy simply installtion and maintenance;   Eurostars geothermal source heat pump is one of the most competitive products, consists of famous brand compressor, electric controlling components, high efficient heat exchanger, etc. With compact structure, elegant appearance, sufficient cooling and heating capacity, high efficiency and maintenance easily.      Eurostars geothermal souce heat pump takes soil underground as heat source, and it is special designed with several working models: heating, cooling, hot water, heating + hot water, cooling +hot water,which is widely used for hotel, villa, hospital, school, etc.  2.Unit main parts introduction-Eurostars geothermal source water chiller heat pump3. Nomenclature-Eurostars water cooled geothermal source water chiller heat pumpES  S     W      25       G     C     Q    1    2      3       4         5      6     7   (1) : ES Eurostars(2) :S Compressor type: S-Scroll type(3) :W Product series: W-Water cooled series(4):25 Product seris NO:(USRT/KW/HP)(5):G G-Geothermal    Omitted:water source                              (6):C Frame type: C-Cabinet type(7): Q Function: H-Heat pump  Q-Heat pump with recovery  Cooling or heating only: omitted4.Technical parameter-Eurostars water cooled geothermal source water chiller heat pumpPlease ask salesman for detailed complete data or visit our website:eurostarschiller.en.made-in-china.comGeothermal Source Heat Pump(Heating-Cooling-Hot Water)ModelESSW10GCQESSW15GCQESSW20GCQESSW25GCQESSW40GCQTechnical ParameterHeating input power Hot waterKW2.132.394.255.088.5Heating capacityKW10.411.620.824.741.6Max outlet water tempºC60 60 60 60 60 COP 4.88 4.85 4.89 4.86 4.89 Cooling input powerCoolingKW1.51.733.46Cooling capacityKW6.87.81416.528Min outlet water temp ºC88888EER 4.53 4.59 4.67 4.85 4.67 Input power HeatingKW2.12.354.154.98.35Heating capacityKW10.511.821.325.242.6Max outlet water tempºC55 55 55 55 55 COP 5.00 5.02 5.13 5.14 5.10 Pipe sizemm2525252532Unit noisedb5050505050N.W.kg100100122129.5229.5G.W.kg132132154161.5279.5Level of protection IPX4IPX4IPX4IPX4IPX4Electric shock proof grade IIIIIUnit Standard ComponentsUnit cabinet Galvanized sheet/ Spray coating / gray colorUnit dimensionmm740*550*1000740*550*1000740*550*1000740*550*10001000*600*1400Packing dimensionmm820*650*1150820*650*1150820*650*1150820*650*11501090*705*1560Refrigerant R407C/2.4kg*1R407C/2.4kg*1R407C/3.3kg*1R407C/3.6kg*1R407C/3.3kg*2Power supply 220V~240V/50Hz380V~415V/50Hz/3phUnit compressor Copeland.Hot water side heat exchanger Shell and tubeA/C side heat exchanger Plate Typesource side heat exchanger Plate Type4-way valve SANHUAThermal expansion valve EmersonAC contactor and thermal relay FujiController Eurostars multiple function controllerProtection function Temperature protection, time protection, water flow protection, antifreeze protection, current protectionWater pressure switch 0.015Mpa :OFF,  0.03Mpa: ONHigh pressure switch 3.0/3.4MPa Low pressure switch 0.15/0.32MPaUnit working mode Heating mode, Cooling mode, Hot water mode, Heating + Hot water mode, Cooling + Hot water mode  Geothermal Source Heat Pump(Heating-Cooling-Hot Water)ModelESSW50GCQESSW55GCQESSW75GCQESSW95GCQ Technical ParameterHeating input power Hot waterKW10.1611.415.120.2 Heating capacityKW49.455.473.197.2 Max outlet water tempºC60 60 60 60  COP 4.86 4.86 4.84 4.81  Cooling input powerCoolingKW6.87.79.913.2 Cooling capacityKW3337.149.467 Min outlet water temp ºC8888 EER 4.85 4.82 4.99 5.08  Input power HeatingKW9.8410.814.519.5 Heating capacityKW50.456.774.899.4 Max outlet water tempºC55 55 55 55  COP 5.12 5.25 5.16 5.10  Pipe sizemm32325065 Unit noisedb55555555 N.W.kg244.5428.5566614.5 G.W.kg294.5498.5656714.5 Level of protection IPX4IPX4IPX4IPX4 Electric shock proof grade IIII Unit Standard ComponentsUnit cabinet Galvanized sheet/ Spray coating / gray colorUnit dimensionmm1000*600*14001320*840*11301750*1120*11602000*1120*1160 Packing dimensionmm1090*705*15601410*940*12901850*1225*13402100*1225*1340 Refrigerant R407C/3.6kg*2R407C/5kg*2R407C/7kg*2R407C/9kg*2 Power supply 380V~415V/50Hz/3phUnit compressor Copeland.Hot water side heat exchanger Shell and tube A/C side heat exchanger Plate Typesource side heat exchanger Plate Type4-way valve SANHUAThermal expansion valve EmersonAC contactor and thermal relay FujiController Eurostars multiple function controllerProtection function Temperature protection, time protection, water flow protection, antifreeze protection, current protectionWater pressure switch 0.015Mpa :OFF,  0.03Mpa: ONHigh pressure switch 3.0/3.4MPa Low pressure switch 0.15/0.32MPaUnit working mode Heating mode, Cooling mode, Hot water mode, Heating + Hot water mode, Cooling + Hot water mode5.Quotation R