80 m3 Liquid Ammonia Storage Tank ( 41 Ton 21.6 Bar NH3 Gas
22mm Pressure Vessel DN3200 ) Butane Tank Horizontal
Storage 40m3 (Pressure Vessel ) for LPG Gas Propane,
Liquid Sulfur Dioxide, Isobutane, Dimethyl Ether
Propane design pressure of 1.77 MPa design temperature 50 ºC
corrosion allowance 1 mm density of 0.42 T/M3Design of liquid
ammonia pressure of 2.16 MPa design temperature 50 ºC corrosion
allowance 2 mm density of 0.52 T/M3Propane design pressure of 1.77
MPa design temperature 50 ºC corrosion allowance 1 mm density of
0.42 T/M3Propane design pressure of 2.16 MPa design temperature 50
ºC corrosion allowance 1 mm density of 0.43 T/M3Liquid sulfur
dioxide design pressure of 0.98 MPa design temperature 50 ºC
corrosion allowance 4 mm density of 1.2 T/M3Gas pressure is 4.1 MPa
design temperature 50 ºC corrosion allowance of 1.4 mmPropane
design pressure of 1.77 MPa design temperature 50 ºC corrosion
allowance 1 mm density of 0.42 T/M3Isobutane design pressure of
0.79 MPa design temperature 50 ºC corrosion allowance 1 mm density
of 0.49 T/M3Dimethyl ether design pressure of 1.15 MPa design
temperature 50 ºC corrosion allowance 1 mm density of 0.58
T/M3Liquid ammonia is a basic chemical raw material, widely
used in metallurgy, textile, papermaking and other industries, and
is a raw material for the synthesis of hydrochloric acid, polyvinyl
chloride, plastics, and pesticides. Liquid ammonia is a
yellow-green oily liquid, highly hazardous (Liquid
ammonia toxicity is classified as Class II in GBZ230), strong
oxidants, and Liquid ammonia gas are not explosive but
can support combustion (classified as B in GB50016).Liquid
ammonia storage tanks mostly use horizontal storage. The
materials of storage tanks are generally low alloy plates specially
used for low alloy pressure vessels such as Q345R and 16MnDR. The
design pressure is 60 ° C, which is the saturated vapor pressure
of Liquid ammonia gas, and the volume is generally 25 ~
100m3. The loading factor is ≤ 0.8. For Liquid ammonia,
consider setting up a storage tank with the largest volume as the
accident tank. Once the storage tank leaks, most of the Liquid
ammonia can be poured into the accident tank. The equipment is
provided with pressure, liquid level and temperature detection. At
the same time, the signal should be concentrated to the DCS system.
The pressure and liquid level detection should be provided with a
root shut-off valveThe inlet and outlet of the storage tank shall
adopt double valves. At the same time, the inlet and outlet of the
storage tank shall be provided with an emergency shut-off valve,
the storage tank shall be provided with a safety valve, and the
safety valve shall be provided with a root shut-off valve. A sewage
pipeline is set at the bottom of the Liquid
ammonia storage tank, and the drainage cycle is determined
according to the concentration of nitrogen trichloride in
the Liquid ammonia. The Liquid ammonia drainage
needs to be processed by an alkali absorption tank. If the tank
farm reserves more than 5 tons, it will constitute a key hazard
source, and the safety protection distance between the tank farm
and the surrounding facilities shall meet the requirements of
project establishment evaluation. Parameter table of liquid
ammonia storage tankNoName Design pressure /
temperatureCapacity(m3)Body specifications / head wall
thickness(mm)Material Net Weight(Kg)Total Length(mm)Level
gauge center distance(mm)Note1Liquid ammonia storage tank DN1400
V=5m32.16/-20/545DN1400×2750×12/12Q345R246535471600Setting pressure
of safety valve is 2.23MPa, the maximum allowable working pressure
is 2.34MPa2Liquid ammonia storage tank DN1600
V=10m32.16/-20/5410DN1600×4400×12/14Q345R370052991800Setting
pressure of safety valve is 2.22MPa, the maximum allowable working
pressure is 2.27MPa3Liquid ammonia storage tank DN1800
V=15m32.16/-20/5415DN1800×5250×14/14Q345R503062492000Setting
pressure of safety valve is 2.22MPa, the maximum allowable working
pressure is 2.24MPa4Liquid ammonia storage tank DN2000
V=20m32.16/-20/5420DN2000×5650×16/16Q345R668067512200Setting
pressure of safety valve is 2.22MPa, the maximum allowable working
pressure is 2.26MPa5Liquid ammonia storage tank DN2200
V=25m32.16/-20/5425DN2200×5770×16/16(15)Q345R762070062400Setting
pressure of safety valve is 2.22MPa, the maximum allowable working
pressure is 2.22MPa6Liquid ammonia storage tank DN2200
V=30m32.16/-20/5430DN2200×7080×16/16(15)Q345R876083162400Setting
pressure of safety valve is 2.22MPa, the maximum allowable working
pressure is 2.22MPa7Liquid ammonia storage tank DN2400
V=30m32.16/-20/5430DN2400×5760×18/18(16.5)Q345R934070982600Setting
pressure of safety valve is 2.22MPa, the maximum allowable working
pressure is 2.22MPa8Liquid ammonia storage tank DN2400
V=40m32.16/-20/5440DN2400×7970×18/18(16.5)Q345R1178093082600Setting
pressure of safety valve is 2.22MPa, the maximum allowable working
pressure is 2.22MPa9Liquid ammonia storage tank DN2800
V=40m32.16/-20/5440DN2800×
Related products about 80 M3 Liquid Ammonia Storage Tank (41 Ton 21.6 Bar NH3 Gas 22mm Pressure Vessel DN3200)
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup