Drink Water Bottle Filling Chiller Air Cooled Industrial Water
Chiller1. Eurostars air cooled water chiller main
components(1)Hermetic scroll compressors-Copeland,
Danfoss(2)Stainless steel centrifugal pump(3)Non ferrous water
piping(4)Stainless steel chilled water insulated tank(5)Stainless
steel evaporator (housed in tank); Plate and shell tube type is
optional(6)Electronic temperature controller with full feature
controls(7)Attractive and durable steel cabinet (SS casing is
optional)(8)Designed for ease of accessibility to components(9)Low
ambient start-up package(10)Split system (remote condenser)
also available2. Air cooled industrial chiller
applicationsIndustrial chillers are used for controlled cooling of
products, mechanisms and factory machinery in a wide range of
industries. Eurostars chillers for industrial applications can be
centralized, where a single chiller serves multiple cooling needs,
or decentralized where each application or machine has its own
chiller. Each approach has its advantages. It is also possible to
have a combination of both centralized and decentralized chillers,
especially if the cooling requirements are the same for some
applications or points of use, but not all. Industrial
chillers are often used in following
area: (1)Eurostars chiller used in food industry:Used for
all types of goods after warning,high speed cooling,let it can
fit for into the jar and bottle.Also it has all kinds of
fermented food need different temperature to stable the
fermented requirement,to improve the fermented food,to make
sure the fermented quality.It is also used in
pharmaceutical,chemical work
refrigeration equipment.(2)Eurostars chiller used in plastic
processing machinery forming mold cooling:It can greatly improve
the plastic surface finish of plastic products.Reduce the
plastic products surface trace and internal stress,let product not
shrinking,not deforming,it is good
for plastic stripping,accelerate product styling.Highly
improve the efficiency of the plastic forming.(3)Eurostars chiller
used in CNC machine tools:Coordinate boring machine,grinding
machine,machining center,combined machine tools and all kinds
of precision machine tool spindle lubrication and hydraulic system
media freezing.It can accurate control
oil temperature. Effectively reduce the thermal
deformation of the machine.3. Air cooled chiller main features(1)
Low Noise(2) High Efficient and Energy Saving(3) Easy Operation and
Installation(4) Compact Exterior(5) High quality(6)
Competitive price(7) CE certificated4. Eurostars air cooled
industrial chiller protection devices(1)Motor overload
protectionIncluding for compressor motors, water pump motors and
fan motors.There are some situations that will cause damage to
motors in an industrial chiller, such as instable voltage, ambient
temperature too high which mostly caused by poor ventilation,
returning water temperature too high, etc. In these cases the motor
running current will get higher than its safe range, which might
damage the motor if keep it working. Built in protection for
overload will shut down the chiller and warn you if the motors are
working unhealthily.(2)Compressor motor overheat
protectionCompressor is the heart of an industrial chiller, it
reflects problem of the whole chiller unit. The situation causes
compressor motor overheat includes poor ventilation, dusty
condenser, refrigerant circuit blocking, lack of refrigerant,
etc.This alarm reminds you to check through the chiller unit,
prevent it from burning out because of unhealthy working
condition. (3)Discharge temperature overhigh
protectionDischarge temperature overhigh normally caused by high
suction temperature, high compressor motor temperature, lack of
refrigerant, etc. It works as supplementary of compressor motor
overheat.(4)High&low pressure protectionHigh pressure normally
caused by poor ventilation, dusty condenser, refrigerant circuit
blocking, etc.Low temperature caused by lack of refrigerant, system
blocking and so on.(5)Returning water overheat protectionChiller
supply cold water to cool the production process, normally the
returning water temperature will be 3ºC to 8ºC higher
than supplied water. If the chiller is not creating cooling energy,
or the chiller capacity is not enough for the application, the
temperature in the circuit will get higher and higher. This will
cause damage for the production even the equipment.While a chiller
got an alarm function for returning water temperature, we can learn
the situation promptly and make reaction.(6)Low water flow/level
protectionFor a chiller with no open-circuit water tank, there will
be a water flow switch to make sure the water circuit is working,
preventing both production process and chiller unit from harmed by
circuit blocking or water leaking.(7)Phase protectionIf an
industrial chiller was falsely wired, motors will revert, which is
a serious problem for all the motors. Phase protection will remind
you to connect the power in a right
Related products about Drink Water Bottle Filling Chiller Air Cooled Industrial Water Chiller
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup