33kv 1600kVA Dry Type Power Electrical Transformer

GeneralThis production can be used in a wide range of area,especially in the place of high fire protection requirement. ie,mine,oilfield,subway station,power plant , school, shopping center, skyscraper and all indoor configuration system.  STRUCTURE CHARACTERISTICS:Iron core : core applies excellent cold rolling oriental silicon sheet and 45°wholly sloped joint no punching hole structure ; surface of the core is coated with special resin to protect against rusting , elastic materials are cushioned between the clamping parts and core, between the clamping parts and core, between coils and between the core and the base seat to reduce operation noise.Coils: low voltage winding applies double cylinder type or fossil type, high voltage winding applies sectional connection type structure; which is wounded by F class insulated polyester double fibre glass copper conductor and reinforced by fibre glass, epoxy resin proportion is poured and moulded under vacuum state. It has good electric performance and mechanical strength.Temperature control: apply automatic temperature control protection system; realize temperature display, patrol inspection, start and stop air fan, over temperature alarm,tip and communication interface of computer etc functions on demand of users.  References:ISO 1461: Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods.IEC 60076: Power transformers.IEC 60044: Instrument transformers.IEC 60296: Specification for unused mineral insulating oil for transformers and switchgear.IEC 60354: Loading guide for oil - immersed power transformers.IEC 60214: Tap-changers - Part 1: Performance requirements and test methods, Part 2: Application guide.IEC 60512: Connectors for electronic equipment.Technical specification:  Rated capacity (kVA)voltage combinationVector groupLosses(120°kW)No-load current(%)HV(kV)tapping rangeLV(kV)On-load lossNo-load loss30    0.710.193.250    10.272.880    1.380.372.6100    1.570.42.4125    1.850.472.2160    2.130.542.22006   2.530.6222506.3   2.760.722.23156.6±5% Yyno3.470.881.840010 0.4 3.990.981.850010.5±2x2.5% Dyn114.881.161.863011   5.881.341.6630    5.961.31.6800    6.961.521.61000    8.131.771.41250    9.692.091.41600    11.732.451.42000    14.453.051.22500    17.173.61.2  Rated capacity (kVA)voltage combinationVector groupLosses(120°kW)No-load current(%)HV(kV)tapping rangeLV(kV)On-load lossNo-load loss50    1.230.32.3100    1.980.471.9160    2.460.581.7200    2.930.641.6250    3.40.731.5315 ±5% Yyno4.060.841.440020,22 0.4 4.8211.350024,10±2x2.5% Dyn115.761.171.363011,12   6.81.321.2800    8.221.521.11000    9.731.7911250    11.482.0611600    13.792.410.92000    16.292.80.92500    19.273.340.8  /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1