China Suppliers Low Medium Voltage Al Covered Aerial Cable Tree Wire

Product DescriptionAerial Bundled Cables (ABC) ,also named ABC Cable,XLPE/PVC Insulated ABC Service Drop Wire ,PVC Insulated ABC Cable,Aerial Bunch ABC CABLE  are composed of one or more concentric-lay-stranded Aluminum 1350 phase conductors insulated with an extruded layer of cross-linked polyethylene compound and assembled with one neutral conductor of All Aluminum Conductors (AAC); Aluminum-Alloy Conductors 6201-T81 (AAAC); Aluminum Conductors, Steel-Reinforced (ACSR); or Aluminum Conductors, Aluminum-Clad Steel Reinforced (ACSR/AW).APPLICATION For distribution low power overhead networks in metropolitan, urban and rural areas. For supply of remote facilities and villages of temporary and permanent character. For above-ground house connections. STANDARDASTM,IEC,GB,NFC 33-209 OR customized products.Detailed Photossingle ABC Overhead Wire, duplex ABC CABLE,Triplex ABC CABLE Service Drop Wire, Quadruplex ABC Aerial Cable  and so on.Product ParametersExecutive Standard:ASTM       Bare neutral MessengerPhase conductor      Code WordAWG or kcmilAAACRated StrengthAACinsulation thickness (m m )Weight (kg/km )       s trading and w ires dia(mm )(lbs )strading and wires dia(mm )      Bay3*6AWG+ 1*30.587/ 1.6811101/4.111.14207     French Coach3*6AWG+ 1*30.587/ 1.6811107/ 1.561.142 13     German Coach3*4AWG+ 1*48.697/2. 1217601/5.1 91.14309     Arabian3*4AWG+ 1*48.697/2. 1217607/ 1.961.14316     Belgian3*2AWG+ 1*77.477/2.6728007/2.471.14476     Shet land3*1/0AWG+ 1*123.37/3.37446019/ 1.891.52768     Thoroughbred3*2/0AWG+ 1*155.47/3.78539019/2.131.52945     Trotter3*2/0AWG+ 1*195.77/4.25679019/2.391.521166     Walking3*4/0AWG+ 1*246.97/4.77856019/2.681.521442                 Executive Standard:NFC                 Nom inal  Average diameter of Average                  insulation thickness     cross-section aeraWire number in ConductorMax resistance at 20conductorRated Strength    Descriptionmm 2No.Ohm /k mMin(m m )Max(m m )KNm m    PHASE, NEUTRAL,and PUBLIC HIGHTING1671.914.65.11.91.2    2571.25.86.3 1.4    3570.8686.87.3 1.6    5070.6417.98.4 1.6    70120.4439.710.2 1.8    95190.321112 1.8    120190.2531213.1 1.8    150190.20613.915 1.7    PORTER54.670.639.29.6 1.6    7070.51010.2 1.5    95190.34312.212.927.51.6                Executive Standard:IEC1    PhasePhasePhase Max. D.C.    AAC+UV-XLPECompact ConductorUV-XLPE InsulationApprox.Overall Diam eterRes is tance of Conductor at 20ºC    No.X Norm al Cross Section of CoresNo.of Al WiresOverall DiameterNormal ThicknessMin.Diameter      No. X m m 2-m mm mm mm mm mohm /k m    1 X 107/1.354.0510.86.056.053.08    1 X 167/1.704.81.20.987.27.21.91    1 X 257/2.2461.20.988.48.41.2    1 X 357/2.5871.41.169.89.80.868    1 X 507/3.008.31.41.1611.111.10.641    1 X 7019/2.159.81.41.1612.612.60.443    1 X 9519/2.5811.61.61.3414.814.80.32    1 X 12018/3.00131.61.3416.216.20.253    1 X 15030/2.5814.61.81.5218.218.20.206    1 X 18536/2.5816.221.720.220.20.164    1 X 24036/3.0018.42.21.8822.822.80.125    2 X 107/1.354.0510.86.0512.13.08    2 X 167/1.704.81.20.987.214.41.91    2 X 257/2.2461.20.988.416.81.2    2 X 357/2.5871.41.169.819.60.868    2 X 507/3.008.31.41.1611.122.20.641    2 X 7019/2.159.81.41.1612.625.20.443    2 X 9519/2.5811.61.61.3414.829.60.32    2 X 12018/3.00131.61.3416.232.40.253    2 X 15030/2.5814.61.81.5218.236.40.206    2 X 18536/2.5816.221.720.240.40.164    2 X 24036/3.0018.42.21.8822.845.60.125    3 X 107/1.354.0510.86.0513.073.08    3 X 167/1.704.81.20.987.215.551.91    3 X 257/2.2461.20.988.418.141.2    3 X 357/2.5871.41.169.821.170.868    3 X 507/3.008.31.41.1611.123.980.641    3 X 7019/2.159.81.41.1612.627.220.443    3 X 9519/2.5811.61.61.3414.831.970.32    3 X 12018/3.00131.61.3416.234.990.253    3 X 15030/2.5814.61.81.5218.239.310.206    3 X 18536/2.5816.221.720.243.630.164    3 X 24036/3.0018.42.21.8822.849.250.125    4 X 107/1.354.0510.86.0514.643.08    4 X 167/1.704.81.20.987.217.421.91    4 X 257/2.2461.20.988.420.331.2    4 X 357/2.5871.41.169.823.720.868    4 X 507/3.008.31.41.1611.126.860.641    4 X 7019/2.159.81.41.1612.630.490.443    4 X 9519/2.5811.61.61.3414.835.820.32    4 X 12018/3.00131.61.3416.239.20.253    4 X 15030/2.5814.61.81.5218.244.040.206    4 X 18536/2.5816.221.720.248.880.164    4 X 24036/3.0018.42.21.8822.855.180.125                Executive Standard:IEC2   PhaseNeutralPhaseNeutral Max. D.C.  AAC+UV-XLPEAAACCompact ConductorUV-XLPE Ins ulationConductor Resistance of Conductor at 20ºC  No.X Norm al Cr os sNo.X Norm al Cross     Approx. Overall Diam eter    Section of CoresSection of CoresNo.of Al.WireOverall Dia.Norm al Thick nessMin.No./Dia. of Al Alloy Wire PhaseNeutral  No. X m m 2No. X m m 2-m mm mMin.No./m mm mohm /k mohm /k m  1 X 161 X 167/1.704.81.20.987/1.7012.31.912.217  1 X 251 X 257/2.2461.20.987/2.1014.71.21.393  1 X 351 X 357/2.5871.41.167/2.5017.30.8681.007  1 X 501 X 507/3.008.31.41.167/3.0020.10.6410.744  1 X 701 X 7019/2.159.81.41.167/3.5023.10.4430.514  1 X 951 X 9519/2.5811.61.61.3419/2.5027.30.320.371  1 X 1201