Technical
consultant Susan STP
Splitter Three in one STP splitter (Built-in integrator
selectable)The product descriptionSTP with an selectable built-in
integrator that outputs a three-way Rogowski coil signal through an
RJ45 port or 8 Pin. Power supply 3.3 ~ 5V , 150mV, 333mV, 500mV,
1V, 1.5V, 3V AC output is optional.AdvantagePortable mini, easy for
installationl Analog connection diagramSize chartRJ45
connector definitionSpecification MODELSTPRated output
100A600A1000A3000A6000A ....Rated output333mV ACMaximum
Output(overload)3V rmsPower supply3.3V-5V DCPower
consumption≤20mWBandwidth20Hz-2kHzRead Accuracy1% typical at
1%(≥10A) to 200% of rated Current @25ºCLinearity±0.2% (5% - 200%
)Phase error≤0.5°Minimum Current measurement0.5A (Ripple
100mA)Output on 0A (zero drift)≤2mVTemperature
drift200ppm/ºCOperating temperature-20ºC - 70ºCStorage
temperature-30ºC - 90ºCRelative humidity:80% max.without
condensationProtection degree:IP20Other requirements, please
contact us to OEM.Safety instructionsThe coil is only safe if used
within the appropriate parameters. Please read the following
instructions carefullyYou can download the latest product
instructions on our rogowski website.Warning!Ignoring
this warning can lead to serious danger!The Roche coil can only be
installed and operated by professionals with electrical training
and qualifications.The installation or operation shall comply with
the applicable national security regulations and the relevant
manufacturer's instructions.Used in electrical or electronic
equipment that meets parameters and safety requirements..Electric
shock warning!Some parts of the module may carry dangerous voltages
when operating the Roche coil.The user should ensure that all
necessary measures are taken to prevent electric shock.A Roche coil
is a built-in device containing conductive parts that should not be
touched after installation.A protective cover or additional
insulation may be required.When the equipment breaks down and needs
to be repaired.Unless it is confirmed that there are no hazardous
live modules in or near this power system, operations such as
maintenance should be carried out after the main power supply is
disconnected.Only when properly transported, stored, installed, and
carefully operated and maintained can the coil be safely and
trouble-free.Attention!Do not damage the coil. Twisting, pricking,
over-squeezing, over-bending will greatly reduce the accuracy and
service life of the equipment.What is a Rogowski coil?Rogowski
coils have been used for the detection and measurement of electric
currents for decades. They are based on a simple principle: an
"air-cored" coil is placed around the conductor in a toroidal
fashion and the magnetic field produced by the current
induces a voltage in the coil. The voltage output is
proportional to the rate of change of current. This voltage is
integrated, thus producing an output proportional to the
current.By using precision winding techniques, especially developed
for the purpose, the coils are manufactured so that their output is
not influenced by the position of the conductor within the
toroid, and to reject interference from external magnetic fields
caused, for example, from nearby conductors.Basically, a
Rogowski coil current measuring system consists of a combination of
a coil and conditioning electronics.Rogowski coil current
transducers are used for the AC measurement.They can be used in
similar circumstances to current transformers but for many
applications they have considerable advantages:• Wide dynamic
range.• High linearity.• Very useful with large size or awkward
shaped conductors or in places with limited access. Thanks to the
structure without hard core, the coil can be easily
manufactured according to the application or to the available
space.• Unlike traditional current transducers, there is no danger
from open-circuited secondaries.• They cannot be damaged by large
overloads.• They are non-intrusive. They draw no power from the
main circuit carrying the current to be measured.• They are also
light weighted and in some applications are light enough to be
suspended on the conductor being measured.The transducer does not
measure direct currents but, unlike a current transformer, it can
carry out accurate measurements of AC component even if there
is a large superimposed DC component, since there is no iron core
causing saturation. This feature is particularly useful for
measuring ripple currents for example in battery charging
systems.MEATROL Rogowski coil Model No.
Definition:DescriptionConnector modelWindow size BSignal cable
length ERatioModel No.
Calibrated(mV/kA@50Hz)Uncalibrated(mV/kA@50Hz)Ø 6 Mini typewith
fixing ribbon
tiesMRC162m50(60mV/kA@60Hz)60(72mV/kA@60Hz)MRC-16-2m-5024MRC-24-2m-5036MRC-36-2m-50Ø8
Rotate bayonet typeEasy inst
Related products about Promotion Rogowski Coil Current Transducer STP with Built in Integrator Spliter Current Converter
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup