Adapter Cable with Fakar Head MCX Connector

FAKRA Connector CharacteristicsElectrical CharacteristicsThe FInishImpedance50ΩBodyNickelFrequency range0-4GHzCenter contactGoldV.S.W.R93Dia.(approx)mm0.93JacketMaterial---FEP Nom. Thicknessmm0.10 Color---Gray Dia.(approx)mm1.13+0.10/-0.062.3 Characteristics:Test ItemUnitSpecified ValueNoteAppearance-Faultless in visible-Temperature ratingºC150-Voltage RatingV250-Inner Conductor Resistance(at 20ºC)Ω/kmMax. 597at 20ºCInsulation Resistance 1>(at 20ºC)MΩ-kmMin. 1500at 20ºCDielectirc strength Delectirc core: No breakdown at AC 1.5KV for 0.15secSpark test Jacket: No breakdown at AC 1.5KV for 0.15secSpark test No breakdown at AC 500V for 1minOuter conductor to inner conductorCapacitancepF/mNom. 98At 1KHzCharacteristic impedance(at D-TDR)Ω50±2TDR MethodAttenuationdB/m2.01.0GHz2.92.0GHz3.63.0GHz4.24.0GHz4.75.0GHz5.26.0GHzCross section of RF1.13 Cable  IPEX Specifications3.1 Test conditionUnless otherwise specified,all tests and measurements shall be performed under the following conditions in accordance with MIL-STD-202Temperature: 288~308K(15~35°C)Humidity:45~75%RH3.2 Electrical 1) Contact ResistanceA. Testing: Solder the receptacle connector to the test board and mate the plug connector together, then measure the contact resistance as shown in Fig.1 buy the four terminal method. Apply the low level condition in accordance with MIL-STD-202, Method 307.Open circuit voltage: 20mA MAX.Circuit current: 10mA MAX. (DC or AC 1kHz)Contact resistance of inner contact:-Contact resistance of ground contact:-B.Requirements: Contact resistance of inner contact initial 20 milli-ohm MAX. After testing25 milli-ohm MAX.Contact resistance of ground contact initial 10 milli-ohm MAX. After testing 15 milli-ohm MAX.2)Insulation resistanceA.Testing: Mate the plug and receptacle conntector together, then apply DC 100V between the inner contact and the ground contact in accordance with MIL-STD-202, Method 302. B.Requirements: Initial 500 Mohm MIN. After testing 100Mohm MIN.  3)Dielectric with standing voltageA.Testing: Mate the receptacle and plug conntector together, then apply AC 100V rms between the inner contact and the ground contact for a minute in accordance with MIL-STD-202, Method 301. B.Requirements: No creeping discharge, flashover, nor insulator breakdown shall occur.  4)VSWRA.Testing: Measure the VSWR as shown in Fig.3 by the network analyzer.     Frequency: 100M~6GHzB.Requirements: Plug 1.3 MAX.at 0.1-3GHz  1.5 MAX. at 3-6GHz   Receptacle 1.3 MAX. at 0.1-3GHz. 1.4 MAX. at 3-6GHz  /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1