MPPT Solar Charge Controller 12V 24V 40AMP

Solar Regulator -Solar Charger Controller with MPPT 12V/24V/48V 40AmpProduct Features1. High converting efficiency higher than 97%for minimizing energy loss2. Build-in MPPT tracker for optimizing the power transformation3. Reversed current protection for preventing equipment damage4. Automatic battery temperature compensation for long-term reliability5. Capable of selecting different charging mode for various type of batteries6. Capable of connecting additional DC load for wider applications7. Three stage charge control system(bulk, absorption, and float mode)with temperaturecompensation8. LED indicators display charge status in real time9. Pulse width modulation(PWM)topology combined with a multi-stage charge control algorithm leads to superior charging and enhanced batteryperformanceProduct performanceMODEL SL-40ARated Voltage 12/24VDCRated charge current 40ALoad current 15AInput voltage rang 15-55VDCMax. PV open circuitArray voltage 55VDTypical idle consumption 5s 1.5*inom>20s1.25*inom temperature controlledBulk charge 14.6V (default) 29.2V (default)Floating charge 13.4V (default) 26.8V (default)Equalization charge 14.0V (default) 28.0V (default)Over charge disconnection 14.8V 29.6VOver charge recovery 13.6V 27.2VOver discharge disconnection 10.8V(default) 21.6V(default)Over discharge reconnection 12.3V 24.6VTemperature compensation -13.2mv/C -26.4mv/CLead acid battery setting AdjustableNicad battery setting AdjustableLoad control mode1. Low Voltage Reconnect (LVR): Adjustable2. Low Voltage Disconnect (LVR): Automatic Disconnection3. Reconnection: Includes warning flash before disconnect and reconnectLow voltage reconnect 12.0-14.0Vdc 24.0-28.0VdcLow voltage disconnect 10.5-12.5Vdc 21.0-25.0VdcAmbient temperature 0-40C (full load) 40-0C (de-rating)Altitude Operating 5000m, Non-operating 16000mProtection class IP21Battery temperature sensor BTS optional remote batter temperatureSensor for increased charging precisionMODEL   SL-40ARated Voltage       12/24VDCRated charge current   40ALoad  current           15AInput voltage rang   15-55VDCMax. PV open circuit array  voltage   55VDTypical idle consumption           < 10mAOverload protection (DC load)  2.0*inom> 5s              1.5*inom> 20s   1.25*inom temperature controlledBulk charge14.6V (default)29.2V (default)Floating charge                                         13.4V (default)26.8V (default)Equalization charge14.0V (default)28.0V (default)Over charge disconnection                 14.8V                               29.6VOver charge recovery   13.6V27.2VOver discharge disconnection     10.8V(default)21.6V(default)Over discharge reconnection   12.3V24.6VTemperature compensation                  -13.2mv/C-26.4mv/CLead acid battery setting AdjustableNicad battery setting                             Adjustable  Load control mode                               1.         Low Voltage Reconnect (LVR): Adjustable 2.         Low Voltage Disconnect (LVR): Automatic Disconnection 3. Reconnection: Includes warning flash before disconnect       and reconnectLow voltage reconnect                                12.0-14.0Vdc24.0-28.0VdcLow voltage disconnect                                        10.5-12.5Vdc21.0-25.0VdcAmbient temperature                             0-40C (full load) 40-0C (de-rating)AltitudeOperating 5000m, Non-operating 16000mProtection class               IP21Battery temperature sensor           BTS optional remote batter temperature sensor for increased charging precision