Wtsensor PCM260h CE Piezoresistive Silicon Water Tank Level Measurement Sensor

Product overview  PCM260H Submersible Level Transmitter accurately measures static pressure of the liquid proportional to the level depth using high performance piezoresistive diffused silicon pressure sensor as the measuring element. The result is converted to standard current signal output through signal conditioning circuit, establishing the linear corresponding relation between the output signal and liquid depth to complete the measurement of the liquid depth. The product has advantages of high precision and small volume. Submerse it directly into liquid, the height between the end of the transmitter to the liquid surface is measured easily. The product is applicable to the measurement and control of the liquid level in the petroleum, chemical industry, power plant, urban water supply and hydrological exploration fields FeaturesPiezoresistive diffused silicon pressure sensorProbe insertion measurement method, easy to installFor level measurementMultiple protective structure design, high protection abilityLCD optionVariety of styles, suitable for various industrial applicationsAnti-corrosion stainless steel material adopted, suitable for many occasionsApplicationsWater level measurement in rivers and lakes Level measurement of containers and storage systems Sewage lift pump and pumping station control Sewage, sediment and flood drainage system monitoring Telecommunications equipment,Diesel generator   Performance parameters Pressure range0~0.5m…20m…200m H2OSupply & output4~20mA (18~36V, 24V typical)4~20mA with display (12~36V, 24V typical)1~5V, 0~5V, 0.5~4.5V, 0~10V (12~32V, 24V typical)Operating temp.-20ºC~85ºCMedium temp.-10ºC~70ºCStorage temp.-40ºC~125ºCCompensated temp.0m~10m H2O: 0ºC~60ºC10m~200m H2O: -10ºC~70ºCZero temp. coefficient±1.5%FS (within compensated temp.)Span temp. coefficient±1.5%FS (within compensated temp.)Overpressure200%FS~300%FSMechanical vibration20g (20~5000HZ)Shock100g (11ms)Accuracy0.5%FSInsulation100MΩ/250VDCResponse time≤1ms (Up to 90%FS)Long term stability±0.2%FS/year  ProtectionIP68MaterialLow copper aluminum alloy for junction box; stainless steel for level probePolyurethane wire for cableMedium compatibilityAll kinds of media compatible with stainless steel 304  Electrical connection   Wiring method   Installation instructions (for reference only) 1.Installation in still water (deep wells, pools, liquid tanks, etc.)Installation tips:1) When measuring the level of stationary fluid in an open container, place the level transmitter vertically into the bottom of the container and secure the cable connecting the transmitter to the junction box at the opening of the container.2) When the medium viscosity is relatively large (such as sewage pool), casing or bracket can be installed to ensure that the transmitter can be put into the bottom of the container.3) When doing an open-air installation, the terminal box of the transmitter should be placed in a ventilated and dry place to avoid direct exposure to light and rain, which may cause the shell temperature to be too high or water to get inside and damage the internal circuit board.2. Installation in moving water (rivers, lakes, etc.)Installation tips:1) When measuring the water level in flowing water, when the medium fluctuates greatly, a steel pipe can be inserted in the water channel with an inner diameter of about 50 cm. Make several holes of about Φ5 in diameter on the side of the immersed pipe opposite to the flow direction to allow water to enter the pipe and fix the cable and junction box at the outlet of the pipe.2) When the medium of the water channel fluctuates greatly or the sediment is large, a damping device can be installed to filter the sediment, eliminate the adverse effects of dynamic pressure and wave and ensure the measurement accuracy.3) When installing the product in lightening intensified area, please indicate "Lightning Protection" when placing an order. Meanwhile, it is recommended that users install lightning protection devices at the site and ensure that the product and power supply are reliably grounded to reduce damage to the transmitter caused by lightning.  Pressure range selection Pressure range codePressure referencePressure rangeOverpressureBurst pressureRemark0.5miG0.5m H2O300%FS600%FS 1miG1m H2O300%FS600%FS 1.5miG1.5m H2O300%FS600%FS 2miG2m H2O300%FS600%FS 2.5miG2.5m H2O300%FS600%FS 3miG3m H2O300%FS600%FS 3.5miG3.5m H2O300%FS600%FS 4miG4m H2O300%FS600%FS 4.5miG4.5m H2O300%FS600%FS 5miG5m H2O300%FS600%FS 5.5miG5.5m H2O300%FS600%FS 6miG6m H2O300%FS600%FS 6.5miG6.5m H2O300%FS600%FS 7miG7m H2O300%FS600%FS 8miG8m H2O300%FS600%FS 9miG9m H2O300%FS600%FS 10miG10m H2O200%FS500%FS 12miG12m H2O200%FS500%FS 15miG15m H2O200%FS500%FS 18miG18m H2O200%FS500%FS 20miG20m H2O200%FS500%FS   Cable length selection Pressure range codeMapping relationCodeDefinition0.5miL1.5 L2 L3 L5 L6 L8 L10 L12 L15 L18 L20 L25L1.5Cable length 1.5m1miL1.5 L2 L3 L5 L6 L8 L10 L12 L15 L18 L20 L25L2Cable length 2m1.5miL2 L3 L5 L6 L8 L10