ZN28-12K Fixed Type of Indoor High Voltage Vacuum Circuit Breaker

ZN28-12K Fixed Type of Indoor High Voltage Vacuum Circuit BreakerGeneral Description  ZN28-12K fixed type indoor HV vacuum breaker is used for many kinds of switchgear like XGN2-12(Z).  It is widely used for 12kV voltage systems which is accordance with GB1984-2003 standards Structural characteristics:1.This vacuum circuit breaker adopts air insulation ,it can meet air distance and creepage under nomal run condition.2.The operating mechanism can use CD17or CT19 type mechanism,the outlet curve has good adaptation for the requirements of vacuum interrupters. It has high reliable with characteristic of long life and easy maintenance.3.Convenient for matching with switchgear;convenient and reliable operation:compulsive mechanical interlock way is adopted:meet the "Five Preventions"function.   Applying ambient conditions1.Ambient temperature:-15~+40ºC.2.The height above sea level:≤1000m(besides the special requirements).3.Relative humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.4.Saturated vapor pressure:the average pressure of a day should be no more than 2.2kPa:the  average pressure of a month should be no more than 1.8kPa.5.Earthquake intensity:not exceed 8 degrees.6.It should be installed in the places without fire,explosion,serious filth, chemical erosion and violent vibration.  Main Technical SpecificationS.NNameUnitData1Rated voltagekV122Rated frequencyHz50/603Rated currentA630630  1250  160010001000160020001250125020002500   31504Rated short circuit breaking current   kA  20   25   31.5   405Rated peak withstand current   kA  50   63    80   1006Rated short-circuit duration    s                            47Rated power frequency withstand voltageBetween phases,phase to  ground   kV                           42Between gaps   kV                           488Rated lightning impulse withstand voltageBetween phases,phase to ground   kV                            75Between gaps   kV                            859Rated operating sequence O-0.3s-CO-180s-COO-180s-CO-180s-CO(40kA)10Rated source voltage of opening and closing circuit   V~220/-110;-220/11011Rated breaking current of single capacitor bank   A                           63012Rated breaking current of bank to bank capacitor bank   A                           40013Electrical endurance classCycle                             3014Mechanical enduranceCycle                          1000015Operating mechanism type CD17ICD17IICD17IICD17IIICT19ICT19ICT19ICT19II16Clearance between open contactsmm11±117Contact stroke of contacts  mm4±118Out simultaneity of CO operation of three poles  ms≤219Contact bouncing duration at closing operation  ms≤220Closing time   ms50~10021Opening time   ms20~6022Average closing speed   m/s0.6±0.223Average opening speed   m/s1.1±0.224Main circuit resistance of each pole   μΩ≤40≤40   ≤40   ≤3025DC component                       50%(Max.)  Overall outline drawing      Welcome for inquiry and factory visit!/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1