Quick DetailsPlace of Origin: China
(Mainland) Brand
Name: XINCHENG Usage: Power Transformer or
Others Model
Number: WSL Max. Current:
2000A Rated
voltage: Under 110KV Application: Voltage
regulator Type:
non-excitation tap changer Function: Voltage
Regulating Phase
Type: Three Grade No.: 3 - 10 or
others Regulating
Position: Central or Others structures: vertical
type Supply
Ability: 3500 Set/Sets per Month ApplicationWSL cage
vision off circuit tap-switch with positive-negative regulating
Functions and Application Type WSL off-circuit tap changers apply
to single pole or three poles oil immersed transformers with the
max. rated through current of 300A,600A,800A,1000A,1200A and
highest voltage for equipment of 12 kV, 40.5kV,72.5 kV and 126kV.
And the operating position is such: model A is 5 ; mode
B is 11. The rated frequency is 50Hz~60Hz. 1 Normal service
condition of the tap changer 1.1 The temperature of the transformer
oil shall be less than 100, more than -25 1.2 The tap changer shall
be kept in the place with ambient temperature from -25~+40, and the
relative humidity shall be less then 85%. 1.3 Vertical inclination
of the tap changer should not be over 2% when it is installed on
the transformer. 1.4 The tap changer shall be operated in areas
without any corrosive or explosive gases. The
specification of the product is rated voltage 110kV(highest voltage
for equipment 126kV) and below, rated current 2000A and below with
various regulating methods can apply hand-operation and
power-driven on the cover or side of the transformer. WSL Series
off-circuit tap changer is used for oil-immersed transformer with
on-load tap changer. It is usually of cage type structure. The
switch transition type is variable with its inner structure. It has
linear regulating , single-bridge stridden over connection,
double-bridge stridden over connection, Y-Δ transition,
series-parallel connected transition, positive or reverse
regulation ate. This tape changer is classified into two type, one
called tank head type, the other called bell covered type. The
operation method can be classified into two type, one is handled on
the tank head or to the grounding, the other is driven with motor,
They are used for power transformer, rectification transformer or
furnace transformer in following specification range, rated
frequency with 50Hz or 60Hz,highest voltage for equipment with
40.5kV,72.5kV and 126kV,rated current with 250A-2000A.This type of
tap changer can only be operated in transformer under non-energized
condition. The WSL cage vision off circuit tap-switch with
positive-negative regulating is used for oil-immersed off-load
voltage-regulating transformer, with vertical and horizontal cage
structure. According to different inner structures, the connection
mode includes linear regulation, single bridging, twin bridging, Y-
△ conversion, serial-parallel conversion, positive-negative
regulation. Installation way can be tank-cover-type and bell-type.
The tap changer can be widely applicable to power, rectification,
furnace and other transformers with rated frequencies of 50Hz and
60Hz, rated voltages of 35kV, 66kV and 110 kV, and rated currents
of 125A~2000A. This tap changer must be operated under off-circuit
status of transformer Non-excitation tap switch applies to
oil-immersed transformer with 50Hz or 60Hz of rated frequency. In
case of no excitation in transformer (i.e. no winding is charged),
the switch can be operated manually or electrically to change the
tapping position and further to change the transformation ratio,
and by this means, secondary voltage can be adjusted or stabilized.
This type of tap changer is comprised by electric, drive me
chanism, tap changer body and electric controller with two kinds of
specifications standing-type and horizontal-type it is suitable for
oil-immersed furnace transformer with rated voltage 40kV and below,
rated current 630A and below, they must be working under
non-energized condition, it can be operated by electric drive or
handle drive. Feature Product features of round
type electrical device: 1)Transformer cover's round installation
opening is smaller and power balance, so its sealing function is
better than that of the square's. 2)Reduce the complex components
will make the structure more compact and enable high transmission
reliability. 3)The round electric operator operates freely and
steadily with high quality of gear shift and small noise. 4)Round
series electrical device's voltage regulating can reach 30 grades
and above which leave more space for transformer designing. It's
superior to the others. 5)This patent round electrical switch is in
simple structure, advanced function and lower costs. It is
economical and safe! Structure This type
off-circuit tap changer consists of
Related products about Wdl off-Circuit Tap Changers for Transformers
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup