2kVA Single Phase Line Interactive UPS with AVR Long Backup Time Machine

Main Features: 1. Provide Line-Interactive design and true sine wave output 2. Equipped with Boost and Buck AVR to stabilize input voltage 3. User configurable input voltage range and output voltage  4. DC start function enables UPS to be started up without AC power supplied 5. Large built-in charger with power factor corrected 6. Enable to extend runtime with scalable external battery pack 7. Fully protection for overload, short-circuit and over temperature  8. RS232 & dry contact signal for power management software 9. SNMP card slot is available for 2KVA above Applications: Ideal for Home, Office, Bank, ATM, Hub, Modem, Autorotation Door, Emergency light and POS systems. Technical specifications Horse series,0.5K-10KVA   Model Name0.5KL0.5KS1KL1KS1.5KL1.5KS2KL2KS3KL3KSNT-6KLNT-8KLNT-10KSCapacity (VA / Watt)500VA/300W1000VA/700W1500VA/1050W1500VA/900W2000VA/1400W3000VA/2100W6KVA / 4.2KW8KVA /5.6KW10KVA/7KWOverviewPower Factor0.60.70.60.7Outlook TowerTower or Rack (3U)Tower  WaveformTRUE SINE WAVEInputNominal Voltage230VVoltage Range 150-275Vac160V~299VFrequency Range45HZ~60HZSocket Type      Socket+Fuse HolderIEC 320  C19 Socket + Circuit breakerTerminal block +CBOutputNominal Voltage230VACVoltage Range (AC Mode)200V~253VVoltage Range (Batt. Mode)230±6%230V±3%Frequency Range(50/60Hz)±0.5%Socket Q'ty (Backup+Surge) IEC320-C13x2  or Customized by customer requirementIEC 320 C14*8PCS ;IEC C320 C20*1PCSTerminal blockIEC 320 C14*8pcs + Terminal blockOverload ProtectionOverload Protection (AC Mode) >120%    1min S/D  Alarm (Fuse or C.B Protection)Overload Protection (Batt Mode)1>120%->15Sec S/D,    >140%->immed UPS Off.110~140%->20Sec, >140%->5Sec.BatteryVolatge 12VDC24VDC 36Vdc24VDC 48VQuantityN/C12V7AH*1PCSN/C12V/7ah*2pcsN/C12v/9ah*2pcsN/C12V7AH*4PCSN/C12V12AH*4PCSN/CN/C12V12AH * 12PCSCold Start (DC Start)YesHot ReplacementYesCharger Current10Amax1.5Amax15Amax1.5Amax20A max1.5Amax20AMAX2A20AMAX2A30A MAX30AMAX5AmaxCharger Over ProtectionYesCharging When UPS offYesData LineNetwork Protection(Optional)N/CRJ45 (1 in/1 out)N/CCommunicationIntelligent InterfaceRS232 OR USBSNMP slotOptionalDisplay LED StatusLine,Batt Mode/charging,Overload,FaultLine,Batt Mode/charging,Overload/Fault;battery capacity; load sizeLine/Batt Mode,AVR ,Battery cabacity ;Load size;Overload,Fault,Batt ReplacementLCD (OPTIONAL)O/P voltage  ,Input voltage and frequence;battery capacity ;Load size.O/P voltage  ,Input voltage and frequence;battery capacity ;Load size.Model ConformanceSafety & EMC ApprovedCE/TUV/FCCPhysicialDimension(DxWxH)122*193*360mm150*220*390150*220*390455x430x135(mm)420*190*335(mm)540*340*710(mm)Net Weight6.5kg8.5kg9.5kg13kg11KG18KG28KG21.5KG34.5KG38.25KG60KG102KGAmbientTemperature0~45°Related Humidity10%~90%(no condensation)Altutide1500m  L for long backup time,S for standard backup time Specifications subject to change without prior notice /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1