High Frequency Modular UPS with Power Module 30kw 40kw

HPM series UPS is developed as a high frequency on line modular UPS for medium and large data center, adopting fully digital control technology, fully guarantee power supply to operate reliably and stably; diversified option of modular power, accurately position user side requirements; flexible redundancy design greatly increase the system availabity, user can realize expansion as demand, and modular structure greatly increase the convenience for maintenance.General FeaturesAdopting digital control design, and the control system is more reliableHigh power density design, capacity of single power module is 6KVA/ 10KVA/ 15KVA/ 20KVA/ 25KVA/ 30KVA/ 40KVA, the height of all these modules is 3U.The power of system ranged from 6KVA to 520KVA corresponds to the number of parallel power modules from 1 to 13Redundant control system, each power module is equipped independent control system, and control itself independently according to the sharing message, and the fault module separates from the system automaticallySupport parallel expansion for cabinet, and  parallel expansion is up to 4 cabinets.Voltage of batteries can be configured flexibly, 1 input 1 output/ 3 input 1 output ±96Vdc/ ±108Vdc/ ±120Vdc(16/18/20PCS)selectable; 3 input 3 output±216Vdc/±228Vdc/±240Vdc (32/34/ 36/38/40PCS) selectableIntelligent charging mode, Charging current can be configured , there are 3 charging mode  which are constant current mode,constant voltage mode,floating charging mode, and the charging mode can be transfer smoothly.Technical SpecificationMODELHPM3325-250KVAHPM3330-90KVAHPM3330-150KVAHPM3330-300KVAHPM3340-200KVAHPM3340-320KVAHPM3340-400KVAHPM3340-520KVAHPM3340-800KVAHPM3340-1280KVA HPM3340-1560KVACapacity (VA/Watts)UPS cabinet 250k / 225k90k / 81k 150k / 135k300k / 270k200k/180k320k/288k400k / 360k520k / 468k800k / 720k1280k / 1152k1560k / 1404kHPM module   25k / 22.5k 25k / 22.5k, 30k / 27k40k / 36kINPUTNominal voltage380/400/415Vac, (3Ph+N+PE) Operating voltage range208~478Vac for half load; 305~478Va c for full load Operating frequency range40~70HzPower factor≥0.99Harmonic distortion (THDi)3%(100% non-linear load)Bypass voltage range380Vac Max.voltage: +25%(optional +10%,+15%,+20% )400Vac Max.voltage: +20% (optional +10%,+15%)415Vac Max.voltage: +15% (optional +10%)Min.voltage: -45% (optional -20%,-30%)Bypass frequency range Frequency synchronize tracing range:±10%Generator accessSupportOUTPUTRated voltage380/400/415Vac(3Ph+N+PE)Power factor0.9Voltage regulation±1%FrequencyLine mode±1%/±2%/±4%/±5%/±10% of the rated frequency(optional)Bat. mode(50/60±0.1%)HzCrest factor3:1Harmonic distortion (THDv)≤2% with linear load≤5% with non-linear load  Efficiency95.00%BATTERYBattery voltage±192/±204/±216/±228/±240Vdc; Battery quantity(optional)Charging current(A)UPS cabinet 60A (Max.)30A (Max.)50A (Max.)100A (Max.)50A (Max.)80A (Max.)100A (Max.)130A (Max.)200A (Max.)320A (Max.)390A (Max.)HPM module 6A (Max.)  25kVA:6A (Max.) / 30kVA:10A (Max.)10A (Max.)Backup time Depends on the capacity of external batteriesSYSTEM FEATURESTransfer timeUtility to battery:0ms; Utility to bypass:0msOverloadLine modeLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% turn to bypass mode immediatelyBat. modeLoad≤110%: last 10min,≤125%: last 1min,≤150%: last 1S,≥150% shut down UPS immediatelyLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% shut down UPS immediatelyBypass mode Breaker (25kVA:40A) Breaker ( 25kVA:40A / 30kVA:60A) 40kVA:95AShort circuitHold whole systemNoise suppressionComplies with EN62040-2Communication interfaceUPS cabinet : RS232, RS485, Dry contact, Intelligent slot x 2(SNMP card,Relay card optional);HPM series UPS module: RS232 ENVIRONMENTOperating temperature0~40ºCStorage temperature-25~55ºCHumidity range0~95% (Non-condensing)Altitude1500m, derating power for useNoise level