Product DescriptionHigh Precision Power Distribution Cabinet UPS
for Data CenterHigh availability1.Novel and elegant appearance2.The
rack color and style can be customized according to the use
environment3.Support single-sided single main road, single-sided
double main road and double-sided double main road layout4.Flexible
incoming and outgoing modes5.The setting of maintenance surface is
flexible and convenient for inspection and maintenance.Fully
enclosed structure and modular design1.Each functional module is
isolated from each other to prevent the operator from directly
contacting the bus and prevent foreign matters from contacting the
electrical device2.Protection : IP403.All systems comply with the
existing national and international standards and specifications,
and the components of the products have passed strict quality
certificationHigh integration and performance1. Advanced DSP full
digital control makes the protection system control faster, more
accurate and more stable, and comprehensively improves the
reliability.2.The anti-interference ability is enhanced to avoid
the inherent hardware parameter drift and other defects of the
analog controller and ensure the product consistency.3.High
integration and simplified circuit.4.Good performance and highly
integrated products ensure more stable and safe operation of the
equipment.Comprehensive power quality monitoringIt can monitor
complete power quality parameter information and provide key
data1.Main circuit measurement parameters include but are not
limited to three phase voltage, current, frequency, active
power, reactive power, power factor, active electric energy,
reactive electric energy, zero ground voltage, neutral line
current, total harmonic content (THD), 2nd-63rd harmonic, current
voltage unbalance, current K factor (KF), voltage crest factor
(CF), telephone waveform factor (thff), peak voltage, voltage and
current sequence, ambient temperature and humidity.2.Branch
measurement parameters include but are not limited to voltage,
current, frequency, active power, reactive power, power factor,
active electric energy, reactive electric energy, 2-31
harmonicsIntelligent management1.Effective analysis of all power
parameters2.Equipment level energy efficiency management3.Touch
screen visualization4.Effective management and risk early warning
of key data of each loop5.Provide standardized interfaces to easily
connect with third-party systems6.Provide a variety of alarm modes
for fault early warning It is necessary to support the access to
the energy management platform to form energy consumption
classification, sub item and sub regional statistical analysis for
the energy consumption and operation information of the data
center, so as to realize the visualization of energy management,
find out the blind spots of energy consumption, tap the
energy-saving potential, and help customers optimize the use of
energy. Detailed PhotosProduct ParametersNameQuantity ( PCS
)Input Voltage220/380vFrequency50/60Hz±10%2Output
Voltage220V(1Ph+N+PE);380V(3Ph+N+PE)4Capacity10~630ADistribution
ArchitectureSupport single bus, double bus and multi bus
systemsBranch air switch supports fixed switch, hot plug air switch
or hot plug adjustable phase air switchSystem Functionthree phase
voltage, current, frequency, active power, reactive power, power
factor, active electric energy, reactive electric energy, zero
ground voltage, neutral line current, total harmonic content (THD),
2nd-63rd harmonic, current voltage unbalance, current K factor
(KF), voltage crest factor (CF), telephone waveform factor (thff),
peak voltage, voltage and current sequence, ambient temperature and
humidityvoltage, current, frequency, active power, reactive power,
power factor, active electric energy, reactive electric energy,
2-31 harmonicsAccuracyIncoming line: voltage / current level 0.2,
active power / electric energy level 0.5s, reactive power /
electric energy level 1Outgoing line: voltage / current level 0.5,
active power / active electric energy / reactive power / reactive
electric energy level 1SPDStandard C-level surge protection: 20KA,
40KADisplayStandard 7-inch touch screen, optional 10 inch or
aboveCommunication interfaceOne way RS485 Modbus-RTUOne way RJ45
10/100m, TCP/IP Modbus Protocol
(optional)Dimension600/800(W)*1000/1100/1200(D)*2000/2200(H)mmPackaging
& ShippingCompany ProfileEstablished in 2008, Guangzhou Getwell
Electronics Co., Ltd has been delivering high quality, innovative
products and technologies to the IT industry for over 15 years. We
focus on data center infrastructure design, construction,
manufacturing, operation and maintenance. From 2008 we started to
research and develop Micro Modular data center product and build
own factory. Getwell pays great attention to R&D and its
engineer teams include industrial designer, structure engineers,
software engineers, power distribution engineers and HAVC
engineers.Getwell is aimed at continuous improvement product, qua
Related products about High Precision Power Distribution Cabinet UPS for Data Center
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup