Online UPS Rack /Tower Convertible Eaton 9sx 20kVA 9sx20kpm

Eaton 9SX (AP) UPS provide stable power for critical IT infrastructure device Industrial, Manufacturing and Medical device.The UPS use advanced technology to improve the double conversion efficiency and reduce the dimension. It helps user save both electricity bill and rack space cost. The UPS enhances robust design for hash environment and load. Reduce the application limited and expand the application area.Core featuresInput and output can be configured to 3 phase or 1 phaseBattery voltage can be set from 384VDC to 480VDC13A big charge current reduce racharge time. ABM® technology increases battery service life by 50 percentColorful touch panel. Build in gravity sensor to rotate the screen for rack installation and tower installation automaticlyOnly 3U high, depth less than 600mm. Help IT manager to save rack space costUp to 3 UPS parallel can provide 2+1 redundancy or 3 times power expanding9SX integrates with leading virtualisation environments and cloud orchestrations tools with an optional network card and IPM SoftwareProduct SnapshotPower Rating15 - 20kVAVoltage1 phase 220/230/240V; 3 phase 380/400/415VFrequency50Hz / 60HzTopologyDouble conversionConfigurationRack / Tower ConvertibleUPS ModelsPart NumberPower RatingInput PlugOutput Receptacles (VA/Watts)  Eaton 9SX Rack/Tower9SX15KPM15000 / 15000HardwiredHardwired9SX20KPM20000 / 20000HardwiredHardwiredEaton 9SX 20kVA RT3U GeneralTopologyDouble conversionConfigurationRack/TowerPart Number9SX20KPMRating (VA/Watts)20000/20000Dimensions (H x W x D, mm)129 x 438 x 589Weight (kg)23.7Warranty1 year Electrical InputConnectionHardwired - see manual for terminal block layoutInput Voltage Range160V~300V full load; 100~160V linear deratingNominal Voltage1 phase 220/230/240V; 3 phase 380/400/415VFrequency50/60 Hz autoselectionFrequency Range40-70 HzInput Power Factor1THDI≤3% linear load; ≤5% non-linear load Electrical OutputVoltages1 phase 220/230/240V; 3 phase 380/400/415VVoltage THD≤1% linear load; ≤3% non-linear loadOutput ReceptaclesHardwired - see manual for terminal block layoutOverload Capacity105% 125% >150%: 0.5sEfficiency (Normal Mode)Up to 96% in Online mode, up to 98.8% in ECO or ESS modeOutput Frequency50/60 Hz autoselectLoad Crest Factor≥3:1 BatteryRuntime(Minutes)Load (Watts)Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc. Actual runtime may vary from +/- 15% around these typical valuesShow:Hover over graph for detailed runtime valuesBattery ManagementABM® and Temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of external battery units.Extended Battery CapabilityEBM CommunicationsUser InterfaceTouchscreen color LCD (with gravity sensor)Communication PortsRS232 DB9; USB 2.0 type-B; programmable dry in/out; Intelligent slotCommunication Slot1 slot for Network-M2 or INDGW-M2 card. Environmental & StandardsAudible Noise≤55dBOperating Temperature0°C ~ 50 °C (0~40 no derating,40°C~ 50°C derating to 50%)Safety markingsCE/TLC/RCM /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1