UPS Double Conversion UPS with Internet Manage
(6-20kVA)EX6K-EX3120KL high frequency online UPS, is a powerful
product range with high adaptability and flexibility. Its cut-edge
digital control technology of DSP (Digital Signal Processor), can
greatly improve the product performance and system reliability, and
deliver a compact integration with higher power density. Meanwhile,
this uninterruptible power supply is especially tailored for all
customers' personalized demands to provide powerful scalable
functions. The unit can be flexibly configured on user's demands.
Application:Servers, data center critical network devices,
sensitive electronic equipment, telecom, bank, hospital, bureau,
traffic, public security, ATM and so on. Main Features:1. Large
Blue Ground LCD digital display shows Detailed Real-Time UPS Status
and parameters. 2. Output Voltage, Frequency parameter and bypass
function can be set via the display. 3. Advanced MCU microprocessor
control technology and DSP technology, ensure long life
reliability. 4.192vdc battery input voltage. 5. Wide input AC
voltage range, Zero transfer time 6. True online double conversion
technology. 7. N+X Parallel Redundancy 8. Excellent Protection
against over voltage, over load, over current, over charge and so
on. 9. Input L and N lines reverse wiring detection, Auto start
when AC back. 10. DC start function, Input PFC revise function. 11.
Humanization bypass output can be adjustable. 12. Smart RS232
communication with monitoring software 13. Intelligent slot
available for AS-400 Dry contact and SNMP card Remote control 14.
Available to work with generators. 15. Lightning, surge, short
circuit, Network/fax/modem surge protection
SPECIFICATIONS: ModelEX1KEX1KLEX2KEX2KLEX3KEX3KLCapacityVA/W1000VA/800W1000VA/800W2000VA/1600W2000VA/1600W3000VA/2400W3000VA/2400WInputNominal
Voltage110/115/120VAC or 200/220/230/240VAC110/115/120VAC or
200/220/230/240VACVoltage Range60~138VAC or 115~300VAC60~138VAC or
115~300VACFrequency Range50Hz :46~54Hz; 60Hz : 56~64Hz50Hz :
46~54Hz : 60Hz; 56~64HzPhaseSingle phase with GroundSingle phase
with GroundPower Factor≥0.97≥0.97OutputVoltage110/115/120 (1±2%)
VAC or 208/220/230/240 (1±2%) VAC110/115/120 (1±2%) VAC or
208/220/230/240 (1±2%) VACFrequency50/60Hz
(Adjustable)
50Hz AC Mode: Follow AC, Battery Mode: 50Hz
(1±0.2%)
60Hz AC Mode: Follow AC, Battery Mode: 60Hz (1±0.2%)50/60Hz
(Adjustable)50Hz AC Mode: Follow AC, Battery Mode: 50Hz
(1±0.2%)60Hz AC Mode: Follow AC, Battery Mode: 60Hz (1±0.2%)Wave
FormPure sine wavePure sine wavePower Factor0.80.8Harmonic
Distortion≤3% THD (Linear load); ≤7% THD (Non-Linear load)≤3% THD
(Linear load); ≤7% THD (Non-linear load)Overload Capacity110%~150%
maintain 30s then turn to bypass output; over 150% maintain
200ms110%~150% maintain 30s then turn to bypass output, over 150%
maintain 200msCurrent Crest
Ratio3:13:1ConnectionsIEC320*4IEC320*6IEC320*6 IEC320*3&Terminal
blockIEC320*3&Terminal blockEfficiencyTO Battery Mode83%83%TO
AC Mode85%85%BatteryTypeSealed free maintenance lead acid
batterySealed free maintenance lead acid batteryNominal DC
voltageBuilt in batteries 12V 7.0AH36VDCBuilt in batteries
12V7.0AH96VDC96VDCQuantity 3 PCSDepend on requested back-up
time8 PCSDepend on requested back-up time8 PCSDepend on requested
back-up timeBack-up Time (Full Load)≥6minDepends on the capacity
of
external battery bank≥7minDepends on the capacity of external
battery bank≥6minDepends on the capacity
of
external battery bankRecharge Time5 hours to 90% of capacity full
dischargeDepends on the capacity of external battery bank5 hours to
90% of capacity full dischargeDepends on the capacity of external
battery bank5 hours to 90% of capacity full dischargeDepends on the
capacity of external battery bankCharge Current
(MAX)1.0A5.0A/8.0A1.0 A5.0A/ 7.0A1.0 A5.0A/ 8.0ACharge Voltage
(VDC)41.1V±0.4V41.1V±0.4V110V±0.6V110V±0.6V110V±0.6V110V±0.6VBypassAutomatic
TransferOn overload and UPS failureOn overload and UPS
failureBefore UPS Power-onDefault "ON" user adjustable to
"YES"Default "ON" user adjustable to "YES"Transfer Time 0ms;
less than 4ms from inverter to bypass and vice versa0ms; less than
4ms from inverter to bypass and vice versaIndicatorsLCD DisplayUPS
status, Battery capacity, loading, Fault
code
(LCD: I/P&O/P voltage&frequency, Battery voltage)UPS
status, Battery capacity, loading, Fault code (LCD: I/P&O/P
voltage&frequency, Battery voltage)Audible
Alarm Bypass,battery mode, Battery low, Overload, FaultBypass,
battery mode, Battery low, Overload, FaultAcoustic NoiseAt 1 Meter
Distance
Related products about UPS Double Conversion UPS with Internet Manage (6-20kVA)
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup