10~200KVA Low Frequency Transformer Based Online UPS Three Phase
380/400/415VacHIGHLIGHTS• Efficiency Control System (ECS)• Robust
and reliable• Galvanic isolation• High overload capacity• Extensive
parallel configurationsTotal protectionDPL series UPS provides
maximum protection and power quality for mission critical loads,
including data centres, industrial processes,
telecommunications, security and electro-medical systems. DPL
series UPS is an on-line double conversion UPS with a transformer
isolated inverter. DPL range includes three-phase input and
single-phase output versions from 10 to 100 kVA, and three-phase
input and output versions from 10 to 200 kVA. All versions are
provided with a 6-pulse thyristor-based rectifier, with or without
optional harmonic filters. A 12-pulse thyristor-based rectifier is
available on request for the 60 and 80 kVA versions with or without
optional harmonic filters.Easy sourceDPL series makes supplying the
UPS from generator sets and MT/BT transformers simpler and more
efficient, reducing power loss in the system and coils, correcting
the power factor and eliminating current harmonics created by the
loads supplied by the UPS.In addition to this, the progressive
rectifier start-up (power walk-in) and the option to reduce battery
charging currents, allow for a reduction in the input current
uptake. This means less demand on the source, which is particularly
useful when the source is a generator set.FlexibilityDPL series is
suitable for a wide range of applications including IT and the most
demanding industrial environments. The UPS is suitable for power
capacitive loads such as blade servers, from 0.9 leading to 0.8
lagging. With a broad range of accessories and options, complex
configurations and system architectures can be achieved to
guarantee maximum power availability and the option to add new UPS
without interruption to existing installation.Battery care system:
maximumbattery careNormally the batteries are kept charged by the
rectifier; when mains power fails, the UPS uses this energy source
to power the consumers. Proper battery care is therefore critical
to ensuring correct UPS operation under emergency conditions. DPL
series of UPS battery care system consists of a series of functions
designed to optimise battery management and achieve the best
performance and operating life possible. DPL series is also
compatible with different battery technologies: vented open lead
acid, VRLA AGM, Gel, NiCd and Lithium.Advanced communications•
Compatible with UPS management system for remote monitoring.•
Advanced multi-platform communications for all operating systems
and network environments.• Double RS232 serial• 2 slots for the
installation of optional communications accessories such as network
adapters, potential free contacts, etc.• EPO: Emergency Power Off
for switching off the UPS via the emergency button• Input for the
connection of the auxiliary contact of an external manual bypass•
Input for synchronisation from an external source• Graphic display
panel for remote
connection SpecificationsModel31 10K31 15K31 20KPhaseThree phase in /Single phase outInputRate capacity10KVA/8KW15KVA/12KW20KVA/16KWRate voltage400VAC(three phase with ground)Turn on voltage range 190-520VAC(three phase) ≤50% load305-520VAC(three phase) ≤100% loadFrequency range46~54Hz or 56~64HzOutputRate voltage220/230/240VACVoltage regulation±1%Line mode frequency46~54Hz or 56~64HzBat mode frequency50Hz or 60HzVoltage harmonic≤3% R load; ≤5% RCD loadCrest ration3:01Line-Bat transfer0msINV-Bypass transfer0msOver load105%±5% 91%Bat mode> 91%BatteryNumber16 or 20Charger voltage218.4VDC/273VDCCharge current (stand)1A/2A/4A adjustable,
default 1ACharge current(long)1A/2A/4A adjustable,
default 4ASize(length*width*height)and weightStand UPS(mm)442*190*688575*190*688Weight(kg)66/7668/7880(only 20 BAT)LongtimeUPS(mm)442*190*318575*190*318Weight(kg)151619EnvironmentWork temperature0ºC~40ºCWork humidity20%~95%Audible noise≤60dBCommunicationRS-232/USB/SNMP card /*
January 22, 2024 19:08:37 */!function(){function s(e,r){var
a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Related products about 10~200kVA Low Frequency Transformer Based Online UPS Three Phase 380/400/415VAC
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup