1.1 Summary Substation, the important AC equipment in Power plants
such as machine background, RTU, transmitters, communications
equipment, lighting, and other incidents generally supply by
the uninterruptible power supply (UPS) .However, the general UPS
equipment price high , large maintenance , higher failure.
Therefore, the electric UPS advantages as following : which can
apply with power substations, power plants operating in the DC
Power System,and direct use he long-life, high-capacity battery,of
DC power operation system, reduce costs, system maintenance,
operating costs.The product is single-phase input / single-phase
output high-quality uninterruptible power supply. That use advanced
SPWM technology, the main circuit use Japan's Mitsubishi IGBT
module, and the driver protection use Japan's Mitsubishi thick film
circuit , has high reliability, full protection, low waveform
distortion .electric supply UPS is specially designed for power
plant , transformer station, with online ,zero delay switch
protection ,mainly used in the fields of high demand to load such
as electric telemechanism , RTU ,DCS system, electric carrier wave
,monitor etc .1.2 Main FeaturesThe BUD series of online UPS for the
three-way input: the first way is AC220V/50Hz, the second way is DC
220V and the third way is bypass input AC220V/50Hz.,The output AC
220 V/50Hz.which.compared to the normal UPS, it has advantages as
following
:
It will not generate a large electromagnetic interference and has
minimal impact to the DC bus because there is a anti-noise
suppressor at the DC input.The DC power input of the UPS fitted
with anti-anti-blocking diode, So the internaDC operation system
work even more safe and stableIt can effective inhibition of the
inrush current, longer battery life for the Buffer with DC circuit
designThere is a isolation transformer installed in the exchange of
power input. So it can meet the DC operation of DC power system on
the bus insulation requirements.DC screen commonly used
valve-sealed battery, which long-life, and therefore use DC power
inverter power source, reliability and long-life ; the capacity of
DC battery screen is larger, using inverter power supply, after the
utility can supply AC for a longer time.1.3 Notice This
specification allows you to easily operate and maintain the system.
You must strictly abide this manual the following
requirements.Before use You must be carefully read this
statementThe equipment must be installed by professionals.It must
be good grounding at the time of installation for avoiding hurting
personal safety Not operating in the high humidity or temperature,
gas or flammable volatile environment.Switch shutdown of all, do
not open the lid closed, so the residual voltage electric shock or
cause damage to machinery.Avoid overload, so as to avoid failure
UPSThe system maintenance and replacement batteries work must be
qualified by technical personnelMachines should be carried
carefully.Opened packaging, inventory annex. If found missing
pieces or damaged during transport, please contact us, you will be
satisfied with the service.2: the system of working principleWhen
the utility power normal ,isolate the monophase AC of 220V
(triphase 380V ),supply the power for the inverter by rectifier
filter, if the Ac input cut off ,the DC screen of provided
for itself of the electric system supply power for the
inverter through against converse diode ,Supply the power supply
for the mainly load by output isolation , if the DC screen cut off,
still have the AC input power supply ,if the inverter over load or
fault ,have the static switching change into bypass power supply
.Manual maintenance the bypass operation: When the main circuit out
of order or require maintenance, the manual bypass switch run, the
running mode: preparing electricity →load.
ModelXND220-3020XND220-3030XND220-3050XND220-3100XND220-3200XND220-3450XND220-3600XND220-31000XND220-32000DC
InputOutput rating voltage (VDC)220Output rating current
(A)10.115.225..349.499222296496988Input DC voltage allowing
range(VDC)180~300AC bypass inputAllowing input voltage
range(VAC)380±15%Input rating
current(A)3.04.57.615.230.368.491.2151..9303.9Bypass switch
time(ms)≤4AC outputRating
capacity(KVA)2.03.05.010204560100200Output rating
power(KW)1.62.44.08.016364880160Output rating voltage and
frequency(VAC/Hz)380VAC/220VAC,50Hz(three phase four wires)Output
rating wire current(A)3.04.67.615.230.168.491.2152304Output voltage
precision(V)380±3%Output frequency precision(Hz)50±0.05waveform
deviation factor (THD)(liner load)≤3%Three-phase load unbalance
ability≤100%dynamic response(load 0←→100%)5%Power factor(PF)0.8Load
ability150%, 10screst factor(CF)3:1Inverted efficiency
(80%resistance load)91%92%Working envirnmentInsulation
strength(input and output)2000VAC,1minute Noise (1meter)≤45dBusing
condition temperature-10ºC~+50ºCtemperature0~90%,no condensingUsing
altitude(m)≤2000machine dimensionwidth,depth,height (mm)550×480×
Related products about Electric UPS Three Phase
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup