Standard IEC/EN 60898-1 IEC/EN 60947-2 Electrical
featuresRated current In A
1, 2, 3, 4, 6, 10, 13, 16, 20,
25, 32, 40, 50,63 Poles 1P, 1P+N, 2P, 3P,
3P+N, 4P 1P, 2P,
3P, 4P Rated voltage Ue V
230/400~240/415Insulation voltage Ui V500Rated
frequency 50/60HzRated
breaking capacity A1000010000Energy limiting class 3 Rated impulse withstand voltage(1.2/50) Uimp V4000Dielectric test voltage at ind. Freq. for 1 min KV21.890Pollution degree 2Power loss per pole Rated
current (A) Max power loss per pole (W) 1,
2, 3, 4, 6, 10 2 16, 20,
25, 32 3.5 40, 50, 63 5Thermo-magnetic
release characteristic B,
C, D (8-12)In Mechanical featuresElectrical life 4000Mechanical lif 20000Contact
position indicator YESProtection degree IP20Reference
temperature
for setting of thermal element ºC 30Ambient temperature (withdaily average≤35ºC) ºC -5...+40Storage temperation ºC -25...+70InstallationTerminal
connection type Cable/U-type
busbar/Pin-type busbarTerminal size top/bottom for
cablemm2 25AWG 18-4Terminal size top/bottom for
busbarmm2 10AWG18-8Tightening torqueN·m2.5In-Ibs.22Mounting On DIN rail EN 60715 (35mm) by means of fast clip deviceConnection From
top
and bottomCombination with accessoriesAuxiliary contact YESShunt release YESUnder
voltage release YESAlarm contant YES
Selectivity Load side: K
NB1-63, KNB1-63HCurve B, CIn (A)Power supply side: RT36-00 (fuse)202536506380100125160Is (kA)≤21.24>12>12>12>12>12>12>1230.71.23.85.36666640.60.92.53.86666660.50.81.92.54.5566610 0.71.42.23.23.666616 1.21.82.635.66620 1.52.22.54.66625 1.322.24.15.5632 1.71.93.84.5640 1.734550 1.52.63.54.563 2.43.34.5
Load side: KNB1-63, KNB1-63HCurve
B, CIn (A)Power supply
side: NM8-100S/H/R1620253240506380100Is (kA)≤100.190.190.30.40.50.50.50.630.816 0.30.40.50.50.50.630.820 0.50.50.50.630.825 0.50.50.630.832 0.50.630.840 0.630.850 0.863 Backup protection
Load
side:K NB1-63, KNB1-63HCurve B, CIn (A)Power supply side: RT16 series40506380100125160Is (kA)1~6404040404040408~104040404040404013404040403535351640404040303030204040404030303025404040403030303240404040303030404040404030303050303030303030306320202020151515
Load side: KNB1-63, KNB1-63HCurve
B, CIn (A)Power supply
side: NM8NM8-125SNM8-125HNM8-125RNM8-250SNM8-250HNM8-250RIs (kA)1~615181815151510~2012151512121232~4012151512121250~60121515121212
Temperature deratingThe maximum permissible current in a circuit breaker depends on the ambient temperature where the circuit breaker is
placed. Ambient temperature is the temperature inside the enclosure or switchboard in which the circuit breakers are installed.
The reference temperature is 30ºC
Ambient temperature -35ºC-30ºC-20ºC-10ºC0ºC10ºC20ºC30ºC40ºC50ºC60ºC70ºCRated current(A) 11.301.261.231.191.151.111.051.000.960.930.880.8322.602.522.462.382.282.202.082.001.921.861.761.6633.903.783.693.573.423.303.123.002.882.792.642.4945.205.044.924.764.564.404.164.003.843.763.523.3267.807.567.387.146.846.606.246.005.765.645.284.981013.2012.7012.5012.0011.5011.1010.6010.009.609.308.908.401621.1220.4820.0019.2018.4017.7616.9616.0015.3614.8814.2413.442026.4025.6025.0024.0023.0022.2021.2020.0019.2018.6017.8016.82533.0032.0031.2530.0028.7527.7526.5025.0024.0023.2522.2521.003242.5641.2840.0038.7237.1235.5233.9232.0030.7229.7628.1626.884053.2051.2050.0048.0046.4044.8042.4040.0038.4037.2035.6033.65067.0065.5063.0060.5058.0056.0053.0050.0048.0046.5044.0041.506383.7981.9080.0176.8673.7170.5666.7863.0060.4858.9055.4452.29When several simultaneously operating circuit breakers are mounted side by side in a small enclosure, the temperature rise inside the enclosure causes a reduction in current rating.
You must then assign the rating (already derated if necessary according to ambient temperatuer) a downrating factor of 0.8.
Company IntroductionWenzhou Korlen Electric Appliances Co., Ltd, It
is a joint venture. My company is a manufacturer including design,
development, produce and sale, professional producing MCB, MCCB,
RCCB and AC contactor etc. Product enterprises. The company owns
import and export power of self-run, expanding Europe and America,
Middle East, Southeast Asia etc. Market, set a good Public praise.
The company have more than 1500 workers, including senior engineer
among them, engineer at inside of more than 100 technician. And
then set up to cover area more than 50 acres, construct area is
more than 38000 square meters of the modern industrial zone,
providing with the forerunner's standard laboratory and various
examination equipments. Under Korlen people to make great effort
unremittingly, designed and developed by oneself, develop and
produce the series of MCB, RCCB filled up local blank, attain
inter-national advanced level, and acquire more than 20 national
patents. The company acquires "30 strong eminent enterprises, top
ten of export income, yueqing star class enterprise, attach
importance to contract and keeps pro
Related products about 125A Miniature Air Circuit Breaker 1p 2p 3p 4p MCB 10ka IEC60898/60947
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup