Nova Dabl-63 6ka 10ka 63A 1p+N 3p+N Electronic Electromagnetic RCBO

DABL-63 6kA 10kA Electronic Residual Current Device RCBO Circuit BreakerIntroductionThe DABL-63 6kA 10kA electronic residual current circuit breaker is designed by Dada engineers for stable operation, precise protection, short opening time, and a high breaking capacity index, all in one small device. The circuit breakers are also produced according to GB 10963 and IEC60898 standards.The circuit breakers are commonly installed for the overload protection of contactors, relays, and other electrical equipment.Main functions: short circuit protection, overload protection and isolation.Model DABL-63 1P+N/2P RCBO Circuit BreakerRated currentRated frequencyRated operating voltageRated residual currentRated insulation voltageImpulse withstand voltageInstantaneous trip typeRated breaking capacityW*H*L6-63A50-60Hz230/400V10,30,100,300A500V6KVB/C/DDABL-63 10KA, DABL-63 6KA36/54mm*80.4mm*72mmDABL-63 3P+N/4P RCBO Circuit BreakerRated currentRated frequencyRated operating voltageRated residual currentRated insulation voltageImpulse withstand voltageInstantaneous trip typeRated breaking capacityW*H*L6-63A50-60Hz230/400V10,30,100,300A500V6KVB/C/DDABL-63 10KA, DABL-63 6KA72/90mm*80.4mm*72mmDABL-63 2P RCBO Circuit BreakerRated currentRated frequencyRated operating voltageRated residual currentRated insulation voltageImpulse withstand voltageInstantaneous trip typeRated breaking capacityW*H*L6-63A50-60Hz230/400V10,30,100,300A500V6KVB/C/DDABL-63 10KA, DABL-63 6KA54mm*95mm*72mmInquiry Form DABL-63 3P+N/4P RCBO Circuit BreakerRated currentRated frequencyRated operating voltageRated residual currentRated insulation voltageImpulse withstand voltageInstantaneous trip typeRated breaking capacityW*H*L6-63A50-60Hz230/400V10,30,100,300A500V6KVB/C/DDABL-63 10KA, DABL-63 6KA72/90mm*95mm*72mm  Technical parameter of DABL-40 electronic residual current circuit breakerProtection grade: IP20Flame retardant grade: grade2Endurance (mechanical): 12,000Endurance (electrical): 6,000Electric wire: 1~25mm2Operating temperature: -5~+40ºCAltitude: ≤2000Relative humidity: +20ºC, ≤90%; +40ºC, ≤50%Class of pollution: 2Installation environment: Avoid obvious shock and vibrationInstallation grade: grade II, grade IIIInstallable accessories of DABL-63 electronic residual current circuit breakerAuxiliary contact, alarm contact, shunt trip, undervoltage trip, overvoltage tripAdvantages·  Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series.·  The most subtle electric shock hazard protection in case of direct contact with conducting parts.·  Independent contact position indicator.·  Wide range of operating temperatures from -25 to +40° С.·  Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection.·  "TEST" button for checking the device's operation and accuracy of connection.·  DABL dimensions correspond to 2-modular item at the expense of constructive elements placement.·  Boosted capability of 6 kA provides for installing AVDTs as incoming protection switches. /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1